Command:
FF
-- Fail Input Off --
Default:
Off
This command has no effect but is retained for backward compatibility purposes.
Command:
FN -- Fail Input On --
Default:
Off
This command has no effect but is retained for backward compatibility purposes.
Command:
aFRn
-- Set Derivative Sampling Period --
Argument:
0 <= n <= 127
Default:
0
This command allows for the adjustment of the derivative sampling interval for servo axis
'a'. The period of this interval can be calculated by the following:
T = (n+1) * S * 0.000100
where "T" is the period in seconds, "n" is the FR command argument and "S" is the sample period
count specified by the Servo Speed (SS) command. For example, if the value previously set by the
SS command is 10 and the value set by the FR command is 1, then the derivative sample period
will be:
(1+1) * 10 * 0.000100 = .002000 S or 2 mS
This command is useful in tuning the PID servo loop to the inertial properties of the system.
Related Commands: RI, SS