SMAC
LAC-25 Technical Reference Manual
57
4.6 Learned Position Storage (LPS) Commands
The LAC-25 uses part of its nonvolatile RAM (NVRAM) to create a 256 item table for storing
positions.
This table overlaps the last 256 registers of the register table.
The LPS table is normally accessed by three commands: Learn Position (LP), Learn Target
(LT) and Move to Position (MP). The purpose for the LPS table is to allow the user to store pre-
determined positions for later use (such as in contouring) as the NVRAM will retain data even when
powered down. In other cases, this table can be built through calculations using the register
commands.
Command:
aLPn
-- Learn Current Position --
Argument:
0 <= n <= 255
This command causes the current position of servo axis 'a' (that position reported by the
Tell Position (TP) command) to be stored in location 'n' of the Learned Position Storage table. This
command is useful for "teaching" target positions to the LAC-25.
Related Commands: LT, MP
Command:
aLTn
-- Learn Target Position --
Argument:
0 <= n <= 255
This command causes the current target position of servo axis 'a' (that position reported by
the Tell Target (TT) command) to be stored in the location 'n' of the Learned Position Storage
table. This command is useful for setting up a table of target positions via a downloading
procedure.
Related Commands: LP, MP
Command:
aMPn -- Move to Index Table Position 'n' --
Argument:
0 <= n <= 255
This command causes the position contained by the Learned Storage Position table
location 'n' to become the new target position. This command will not initiate a motion; therefore,
a Go (GO) command may be required.