Displays and Messages
SB6000U-13:SE2506
SMA America
7-17
Measuring Channels
The communication options support a number of measuring channels and messages
from the Sunny Boy inverters.
The following abbreviations are used:
BFR
B
etriebs
f
ührungs
r
echner (Sequential Control System)
SRR
S
trom
r
egelungs
r
echner (Current Control System)
Measuring Channels
Vpv
:
PV input voltage
Vpv
Setpoint
:
MPPT DC voltage target
Iac
:
Grid current
Vac
:
Grid voltage
Fac
:
Grid frequency
Pac
:
Power fed to grid
Vpv-PE:
PV-voltage to earth (For troubleshooting PV ground faults)
Ipv
:
PV current
E-Total
:
Total energy yield
h-Total
:
Total operation hours
h-on:
h-on indicates how long sufficient DC voltage has been applied to
the Sunny Boy and the Sunny Boy has been active including the time
it was not able to feed to the utility with respect to low DC voltage
or operation in stop mode.
Power On
:
Total system start-up counter
Serial Number
:
Serial number of the Sunny Boy
Mode
:
Current operating mode
Grid Type:
Type of grid the Sunny Boy is connected to
Error
:
Description of fault
http://www.wholesalesolar.com/inverters.html
http://www.wholesalesolar.com/inverters.html