Input Voltage Configuration
4-6
SMA America
SB6000U-13:SE2506
Figure 4-3 Common Utility Voltage Configurations
Figure 4-3 above illustrates commonly used transformer types. Remember, when
connecting the SB6000U to the utility, the phase relationship is not important, but the
voltage
must be compatible.
Utility Configuration Jumpers
The utility configuration jumpers allow the SB6000U to be connected to transformers
where the neutral is not present, such as the 208V and 240V Delta, shown in Figure 4-
3 above. Refer to Figures 4-4 and 4-5 for a description of jumper settings.