Table of Contents
SMA Solar Technology AG
Installation Manual
3
SCCP-JP_NR-IA-en-11
1
Information on this Document.....................................................................................................
4
1.1
Validity .............................................................................................................................................................
1.2
Target Group ...................................................................................................................................................
1.3
Levels of warning messages............................................................................................................................
1.4
Symbols in the Document................................................................................................................................
5
2
Safety ............................................................................................................................................
6
2.1
Intended Use....................................................................................................................................................
2.2
Safety Information ...........................................................................................................................................
7
2.3
Personal Protective Equipment ........................................................................................................................
9
Product Overview ........................................................................................................................ 10
3.1
Design of the Inverter ...................................................................................................................................... 10
3.2
Type Label........................................................................................................................................................ 10
Scope of Delivery ......................................................................................................................... 11
Preparation for Mounting............................................................................................................ 13
5.1
Additionally required mounting material........................................................................................................ 13
5.2
Disconnecting the Inverter............................................................................................................................... 13
Mounting....................................................................................................................................... 14
6.1
Safety during Mounting .................................................................................................................................. 14
6.2
Disassembling the Kick Plates ......................................................................................................................... 14
6.3
Removing the Existing Ventilation Plate.......................................................................................................... 15
6.4
Disassembling the Rear Panel......................................................................................................................... 15
6.5
Mounting the New Rear Panel ....................................................................................................................... 17
6.6
Mounting the Kick Plate for the Sound Absorber .......................................................................................... 18
6.7
Mounting the Ventilation Plate........................................................................................................................ 18
6.8
Mounting the Kick Plate .................................................................................................................................. 19
6.9
Mounting the Silencing Baffle......................................................................................................................... 19
Switching the Inverter On............................................................................................................ 22
8
Dimensions and minimum clearances ........................................................................................ 23
8.1
Dimensions of the Inverter............................................................................................................................... 23
8.2
Minimum Clearances for Outdoor Installation .............................................................................................. 23
Technical Data .............................................................................................................................. 26
10 Contact .......................................................................................................................................... 27
Страница 1: ...SCCP JP_NR IA en 11 98 114400 02 Version 1 1 ENGLISH Installation Manual Retrofitting of the Option Noise Reduction SUNNY CENTRAL CP JP Series...
Страница 2: ...valuation or other proper use is allowed and does not require prior approval SMA Warranty You can download the current warranty conditions from the Internet at www SMA Solar com Trademarks All tradema...
Страница 3: ...nting 13 5 1 Additionally required mounting material 13 5 2 Disconnecting the Inverter 13 6 Mounting 14 6 1 Safety during Mounting 14 6 2 Disassembling the Kick Plates 14 6 3 Removing the Existing Ven...
Страница 4: ...in this document must only be performed by qualified persons Qualified persons must have the following skills Knowledge of how the product works and is operated Training in how to deal with the danger...
Страница 5: ...ation Manual 5 SCCP JP_NR IA en 11 1 4 Symbols in the Document Symbol Explanation Information that is important for a specific topic or goal but is not safety relevant Indicates a requirement for meet...
Страница 6: ...roval from the grid operator Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable standards and directives Any other applicat...
Страница 7: ...PV modules that are exposed to sunlight carry live voltage Touching live cables results in death or serious injury due to electric shock Prior to connecting the DC cables ensure that the DC cables ar...
Страница 8: ...ways close and lock the product Remove the keys Store the keys in a safe place Ensure that no unauthorized persons have access to the closed electrical operating area WARNING Danger to life due to blo...
Страница 9: ...CE Damage to electronic components due to electrostatic discharge Electrostatic discharge can damage or destroy electronic components Observe the ESD safety regulations when working on the product Wea...
Страница 10: ...et You will require the information on the type label to use the product safely and when seeking customer support The type labels must be permanently attached to the product Reading off the serial num...
Страница 11: ...cope of delivery is incomplete or damaged Scope of delivery of the silencing baffle A C B E D H I K F G Figure 2 Scope of delivery Position Quantity Designation A 1 Rear panel silencing baffle includi...
Страница 12: ...SCCP JP_NR IA en 11 12 Scope of delivery of the kick plate set and rear panel D A E B C Figure 3 Scope of delivery Position Quantity Designation A 1 Inverter rear panel B 1 Kick plate set C 1 Ventila...
Страница 13: ...X 30 Storage location for enclosure parts e g padded storage cart Torque wrench socket wrench size 13 5 2 Disconnecting the Inverter The inverter must be disconnected prior to the disassembly of the r...
Страница 14: ...he specified thresholds The humidity thresholds are 15 to 95 Only perform assembly work when the environment is dry and free of dust NOTICE Inverter failure due to improper storage of the enclosure pa...
Страница 15: ...kick plates TX 30 Retain the screws for subsequent mounting of the new kick plates 3 Remove kick plates 4 Dispose of the kick plates in accordance with the locally applicable disposal regulations 6 3...
Страница 16: ...ips off or tilts Weight of the roof 20 kg Wear suitable personal protective equipment for all work on the product Always have two persons disassemble and mount the rear panel Procedure 1 DANGER Danger...
Страница 17: ...sons must be available for disassembling the rear panel The required mounting material must be available see Section 5 1 page 13 The inverter must be sufficiently protected from inclement weather CAUT...
Страница 18: ...30 torque 8 Nm 5x 8 Make sure that the rear panel is correctly mounted 6 6 Mounting the Kick Plate for the Sound Absorber The kick plate must be mounted with an additional air duct on the rear side o...
Страница 19: ...nclosure 2 Screw the previously retained pan head flange screws into the threads 3 Tighten the pan head flange screws with a suitable screw driver TX 30 torque 8 Nm 6 9 Mounting the Silencing Baffle W...
Страница 20: ...ce the cover over the stud bolts 2 Insert a cylindrical screw with contact washer into the top left thread Do not tighten the screw yet 3 Screw five pan head flange screws into the upper threads on th...
Страница 21: ...nuts torque 8 Nm Mounting the Rain Shield Required mounting material 2 cylindrical screws 2 contact washers 6 pan head flange screws Procedure 1 Position the rain shield on the silencing baffle 2 Scre...
Страница 22: ...itching the Inverter On Switching the Inverter On Only switch the inverter on in accordance with the information provided in the inverter documentation Prior to switching the inverter on ensure that a...
Страница 23: ...956 mm 2562 mm 2272 mm 152 mm 1307 mm 1204 mm 652 mm 254 mm Figure 6 Dimensions of the inverter with silencing baffle 8 2 Minimum Clearances for Outdoor Installation For the optimum operation of the i...
Страница 24: ...n 11 24 Minimum clearances for two inverters with mv transformer to be installed outdoors Option 1 Figure 8 Minimum clearance for two inverters with MV transformer Position Designation A Inverter 1 B...
Страница 25: ...CCP JP_NR IA en 11 Option 2 D D A A B B C C 500 mm 1200 mm 300 mm 300 mm 1200 mm 1200 mm Figure 9 Minimum clearance for two inverters with MV transformer Position Designation A Inverter 1 B Inverter 2...
Страница 26: ...ffer from the standard version is shown here You will find the complete overview of the product s technical data in the installation manual General Data Width x height x depth 2562 mm x 2272 mm x 1210...
Страница 27: ...al problems concerning our products contact your service partner Your service partner needs the following information in order to provide you with the necessary assistance Device type Serial number Ty...
Страница 28: ...www SMA Solar com...