background image

2

TOOLS REQUIRED FOR INSTALLATION

•  2.5 mm hex allen wrench
•  5/8” open end wrench for female end for U.S. flex hose fittings
•  Tape Measure
•  Level
•  #2 Philips Screwdriver
•  Carpenters Square

•  Drill
•  Utility Knife
•  Pipe Nipples
•  Pipe Elbows
•  Teflon Tape (NO PIPE DOPE!)

PRIOR TO INSTALLATION

Prior to installing the Sloan BASYS

 Series Faucets, install the items listed 

below. Also, refer to rough-in illustrations.

IMPORTANT:

•  ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLI-

CABLE CODES AND REGULATIONS.

•  FLUSH ALL WATER LINES PRIOR TO MAKING  

CONNECTIONS.

•  KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COM-

PONENT PART DAMAGE! DO NOT USE ANY SEALANT ON COMPRESSION 
FITTINGS.

•  DO NOT REMOVE THE SENSOR LABEL UNTIL AFTER WATER SUPPLY IS 

TURNED ON.

Wall Plate

The BASYS

 Wall Faucet can be installed with or without supplied wall 

plate.

FAUCET ROUGH-IN

EFX-8XX.X0X.10X0

† EFX Faucets are available with a 0.5 gpm 
   (1.9 Lpm) multi-laminar spray, 1.5 gpm 
   (5.7 Lpm) aerated stream, and 1.5 gpm 
   (5.7 Lpm) laminar stream.

8.23”

(209.1 mm)

9.5”

(244 mm)

2” (51 mm)

42°

3.13”  (79.5 mm)

2.43”  (61.8 mm)

3”  (76.4 mm)

1.67”  (42.4 mm)

Содержание BASYS EFX-8

Страница 1: ...ons or organizations who purchase Sloan Valve Company s products directly from Sloan Valve Company for purpose of resale This warranty does not cover the life of the battery THERE ARE NO WARRANTIES WH...

Страница 2: ...IN ACCORDANCE WITH APPLI CABLE CODES AND REGULATIONS FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COM PONENT PART DAMAGE DO NOT USE ANY SEALANT...

Страница 3: ...mm 1 33 33 7 mm MOUNTING ASSEMBLY MOUNTING ASSEMBLY LESS MUD PLATE 4 55 115 5 mm 2 5 63 2 mm 0 12 3 mm 1 4 35 mm 0 8 20 mm 4 84 122 95 mm 4 55 115 5 mm 3 94 100 mm 1 97 50 mm KNOCK OUT FOR MAIN POWER...

Страница 4: ...01 mm C Loop cable and install mud guard to protect wall while finishing D Finish wall and trim mud plate flush to wall E Rotate solenoid cable under battery pack and insert into holder as shown Note...

Страница 5: ...en the supply stop s Rotate the solenoid caddy counter clockwise to a 45 angle to align with the arrow Remove solenoid caddy from the faucet Rotate the purge tube assembly counter clockwise to a 45 an...

Страница 6: ...aterflow will stop and will remeasure environment On Please contact factory for more extensive programming options 3 START UP SEQUENCE ADAPTER BOX MOUNT TO FAUCET TO FAUCET B Remove label from sensor...

Страница 7: ...TY OF APPLICATIONS AND SHOULD NOT REQUIRE RESETTING UNLESS UNDER EXTREME SITUA TIONS HIGH REFLECTION OR LOW LIGHT 2x 1x 5 sec 1x 2x 3x 4x 6x Factory Setting Longer Distance Shorter Distance 7x 8x 5x 1...

Страница 8: ...ugh a 45 angle C Pull solenoid caddy from faucet NOTE Strainer can be removed cleaned and replaced at this time D Insert new solenoid caddy at a 45 angle UNLOCK NOTE TURNING OFF WATER IS NOT NECESSARY...

Страница 9: ...sert NOTE If changing to a different flow rate solenoid caddy must also be changed E Return spray removal tool to storage location NOTE This can only be done once spray head is installed This will loc...

Страница 10: ...D1 blinking while IR adjusts Few seconds IR Adjust OK LED2 on for 2 sec if adjustment OK Battery Low LED1 blinks 3x if battery is less than warning level Only while in detection mode Battery Empty LED...

Страница 11: ...tteries low battery powered models Replace batteries refer to battery replacement on page 7 B Power failure hardwire models Check power supply 5 Faucet delivers only a slow flow or dribble when sensor...

Страница 12: ...all Blue 4 EFX 19 Strainer Filter 5 EFX 1013 A Mounting Assembly 6A EFX 1009 A Bowed Crown Assembly 6B EFX 1010 A Solar Crown Assembly 6C EFX 1018 A Solar Crown with LCD Assembly 7 EFX 1015 A CR P2 Li...