Item #  Part # 

Description

– 

Wall Mount Faucet Assembly

EFX-1002-A  0.5 gpm/1.9 Lpm Multi-Lam Spray Insert (includes insert,  

  

o-ring, 2.5 mm allen key, and removal tool)

 

EFX-1001-A  1.5 gpm/5.7 Lpm Aerated Stream Insert (includes insert,  

  

o-ring, 2.5 mm allen key, and removal tool)

 

EFX-1000-A  1.5 gpm/5.7 Lpm Laminar Stream Insert (includes insert,  

  

o-ring, 2.5 mm allen key, and removal tool)

EFX-1011-A  0.5 gpm/1.9 Lpm Solenoid Valve Caddy Assembly –  

  

Wall (Green)

 

EFX-1012-A  1.5 gpm/5.7 Lpm Solenoid Valve Caddy Assembly –  

  

Wall (Blue)

EFX-19 

Strainer (Filter)

EFX-1013-A  Mounting Assembly

6A 

EFX-1009-A  Bowed Crown Assembly

6B 

EFX-1010-A  Solar Crown Assembly

6C 

EFX-1018-A  Solar Crown with LCD Assembly

EFX-1015-A  CR-P2 Lithium Battery

MIX-60-A 

Mechanical, Below Deck Mixing Valve

MIX-135-A  Thermostatic, Below Deck Mixing Valve

10 

ETF-617-A  Bak-Chek Tee Assembly

11 

EAF-23-A 

Splitter

12 

EAF-24-A 

11-13/16” (300 mm) Extension Cable

 

EAF-25-A 

47-1/4” (1200 mm) Extension Cable

 

EAF-17-A 

126” (3200 mm) Extension Cable

13 

EAF-11 

Plug-in Voltage Adapter (US)

 

EAF-39 

Plug-in Voltage Adapter (UK)

 

EAF-41 

Plug-in Voltage Adapter (EU)

 

EAF-37 

Box Mount Adapter

14 

–– 

Purge Tool

NOTE: If changing flow rate caddy and spray insert must be changed in 

conjunction.

†  Single Supply faucets include Bak-Chek

®

Manufactured by Sloan Valve Company under one or more of the following patents: U.S. 
Patents. Other Patents Pending. BAK-CHEK

®

, BASYS™, Any Application. Any Environment.™

2

4

6A

3

6B

6C

7

10

12

9

13

8

11

1

5

14

Содержание BASYS EFX-8

Страница 1: ...ons or organizations who purchase Sloan Valve Company s products directly from Sloan Valve Company for purpose of resale This warranty does not cover the life of the battery THERE ARE NO WARRANTIES WH...

Страница 2: ...IN ACCORDANCE WITH APPLI CABLE CODES AND REGULATIONS FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COM PONENT PART DAMAGE DO NOT USE ANY SEALANT...

Страница 3: ...mm 1 33 33 7 mm MOUNTING ASSEMBLY MOUNTING ASSEMBLY LESS MUD PLATE 4 55 115 5 mm 2 5 63 2 mm 0 12 3 mm 1 4 35 mm 0 8 20 mm 4 84 122 95 mm 4 55 115 5 mm 3 94 100 mm 1 97 50 mm KNOCK OUT FOR MAIN POWER...

Страница 4: ...01 mm C Loop cable and install mud guard to protect wall while finishing D Finish wall and trim mud plate flush to wall E Rotate solenoid cable under battery pack and insert into holder as shown Note...

Страница 5: ...en the supply stop s Rotate the solenoid caddy counter clockwise to a 45 angle to align with the arrow Remove solenoid caddy from the faucet Rotate the purge tube assembly counter clockwise to a 45 an...

Страница 6: ...aterflow will stop and will remeasure environment On Please contact factory for more extensive programming options 3 START UP SEQUENCE ADAPTER BOX MOUNT TO FAUCET TO FAUCET B Remove label from sensor...

Страница 7: ...TY OF APPLICATIONS AND SHOULD NOT REQUIRE RESETTING UNLESS UNDER EXTREME SITUA TIONS HIGH REFLECTION OR LOW LIGHT 2x 1x 5 sec 1x 2x 3x 4x 6x Factory Setting Longer Distance Shorter Distance 7x 8x 5x 1...

Страница 8: ...ugh a 45 angle C Pull solenoid caddy from faucet NOTE Strainer can be removed cleaned and replaced at this time D Insert new solenoid caddy at a 45 angle UNLOCK NOTE TURNING OFF WATER IS NOT NECESSARY...

Страница 9: ...sert NOTE If changing to a different flow rate solenoid caddy must also be changed E Return spray removal tool to storage location NOTE This can only be done once spray head is installed This will loc...

Страница 10: ...D1 blinking while IR adjusts Few seconds IR Adjust OK LED2 on for 2 sec if adjustment OK Battery Low LED1 blinks 3x if battery is less than warning level Only while in detection mode Battery Empty LED...

Страница 11: ...tteries low battery powered models Replace batteries refer to battery replacement on page 7 B Power failure hardwire models Check power supply 5 Faucet delivers only a slow flow or dribble when sensor...

Страница 12: ...all Blue 4 EFX 19 Strainer Filter 5 EFX 1013 A Mounting Assembly 6A EFX 1009 A Bowed Crown Assembly 6B EFX 1010 A Solar Crown Assembly 6C EFX 1018 A Solar Crown with LCD Assembly 7 EFX 1015 A CR P2 Li...

Отзывы: