4
A
Slide Threaded Adapter fully onto pipe.
B
Sweat solder the Adapter to pipe.
WITH THE EXCEPTION OF THE CONTROL STOP INLET,
DO NOT USE PIPE SEALANT OR PLUMBING GREASE ON
ANY VALVE COMPONENT OR COUPLING!
!!! IMPORTANT !!!
A
Install the Sloan Bak-Chek
®
control stop onto the water supply line
with the outlet positioned as required.
A
Assemble pipe, elbows, couplings, nylon slip gasket, rubber
gaskets and flanges as illustrated on parts page.
B
Insert tube into fixture spud.
C
Hand tighten all couplings.
C
Align flushometer body and securely tighten first the tailpiece
coupling
(1)
, then the vacuum breaker and pipe couplings
(2)
,
and finally the spud coupling
(3)
. Use a wrench to tighten these
couplings in the order shown.
B
Align flushometer directly above the vacuum breaker flush
connection by sliding the flushometer body IN or OUT as needed.
tighten vacuum breaker coupling by hand.
A
Lubricate tailpiece o-ring with water. Insert adjustable tailpiece into
control stop. Tighten tailpiece coupling by hand.
Max. adjustment of Sloan Adjustable Tailpiece is ½” (13 mm) IN
or OUT from the standard 4¾” (121 mm) (C/L of Valve to C/L of
control stop).
If roughing-in measurement exceeds 5¼” (133 mm),
consult factory for longer tailpiece.
NOTE
C/L FIXTURE
C/L SUPPLY
IMPORTANT: WHEN
CUTTING SCORED
PIPE TO LENGTH
LEAVE A MINIMUM
OF 1-1/4” (32 mm)
OF SCORING TO
ENSURE PROPER
ENGAGEMENT
THREADED ADAPTER
WATER SUPPLY PIPE
IRON PIPE NIPPLE OR
COPPER PIPE WITH
SWEAT SOLDER ADAPTER
BAK-CHEK
®
CONTROL STOP
DO NOT USE PIPE
SEALANT ON SCORED SLIP
CONNECTION
1-1/4” (32 mm) MIN.
FLUSHOMETER
BODY
G-44 FRICTION RING
VACUUM BREAKER
COUPLING
2
VACUUM BREAKER
FLUSH CONNECTION
VACUUM
BREAKER
REPAIR KIT
TAILPIECE COUPLING
CONTROL STOP
O-RING
ADJUSTABLE TAILPIECE
1
1 - INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT
HAVE A MALE THREAD)
2 - INSTALL CONTROL STOP ONTO SUPPLY PIPE
3 - INSTALL VACUUM BREAKER FLUSH CONNECTION
4 - INSTALL FLUSHOMETER