6

C

Open control stop. Turn on water supply to flush line of any debris or 

sediment.

B

Remove flushometer cover and lift out inside parts assembly. Install 

flushometer cover wrench tight.

D

Shut off control stop, remove cover and reinstall inside parts assembly. 

Install flushometer cover wrench tight. DO NOT open control stop until 

Step 10.

A

Make sure Control Stop is CLOSED.

A

Turn Power 

ON

. The self adaptive sensor automatically adapts to the 

surrounding environment when 24 volt supply is activated. No manual 

adjustments are required.

Note: It is recommended that all electronic connections be 

tested with the water supply OFF.

B

Start-up mode will take approximately five (5) minutes to complete its 

cycle and is important that no non-permanent target is present at this 

time. A continuous red light visible in sensor window indicates sensor 

is in the start-up mode. If the red light is flashing, this indicates that 

the sensor is picking up a target. Unless this target is a permanent 

fixture in the sensor’s environment (i.e., a wall or stall door), it must 

be removed from the view of the sensor. If this target is permanent, 

the sensor will adapt itself around this target. In this case, the start-

up mode may take up to ten (10) minutes. When the start-up cycle is 

completed, no light is visible in sensor window.

Note: If 24 volt power supply is interrupted at any time 

for more than fifteen (15) seconds, the start-up mode 

automatically repeats itself when power is restored.

C

The self-adaptive sensor is equipped with the sentinel flush 

feature (automatically flushes every twenty-four (24) hours after 

last use).

D

When an object is detected, a steady flashing red light will 

appear in the sensor window. After approximately eight (8) 

to ten (10) seconds, the light will turn off indicating sensor is 

armed and ready to activate solenoid when the object leaves 

the detection area. The solenoid will be activated within two (2) 

to four (4) seconds after non-detection.

A

Adjust control stop to meet the flow rate required for proper cleansing 

of the fixture. Open control stop COUNTERCLOCKWISE 1/2 turn from 

the closed position.

B

Activate flushometer by placing hand in front of OPTIMA Sensor Lens 

for ten (10) seconds and then moving it away.

C

Adjust control stop after each flush until the rate of flow 

delivered properly cleanses the fixture.

SLOAN FLUSHOMETERS ARE ENGINEERED FOR 

QUIET OPERATION. EXCESSIVE WATER FLOW 

CREATES NOISE, WHILE TOO LITTLE WATER FLOW 

MAY NOT SATISFY THE NEEDS OF THE FIXTURE. 

PROPER ADJUSTMENT IS MADE WHEN PLUMBING 

FIXTURE IS CLEANSED AFTER EACH FLUSH 

WITHOUT SPLASHING WATER OUT FROM THE LIP 

AND A QUIET FLUSHING CYCLE IS ACHIEVED.

NEVER OPEN THE CONTROL STOP TO  

WHERE THE FLOW FROM THE VALVE EXCEEDS  

THE FLOW CAPABILITY OF THE FIXTURE.  

IN THE EVENT OF A VALVE FAILURE,  

THE FIXTURE MUST BE ABLE TO ACCOMMODATE  

A CONTINUOUS FLOW FROM THE VALVE.

!!! IMPORTANT !!!

7 - FLUSH OUT SUPPLY LINE

8 - POWER, START-UP MODE, AND ACTIVATION/DETECTION

9 - TURN WATER ON AND ADJUST CONTROL STOP

Содержание 150 ES-SM

Страница 1: ...one 1 year for special finishes SF faucets PWT electronics and 30 days for PWT software from date of first purchase During this period Sloan Valve Company will at its option repair replace or refund...

Страница 2: ...TICAL Failure to properly position the electrical boxes to the plumbing rough in will result in improper installation and impair product performance All tradesmen plumbers electricians tile setters et...

Страница 3: ...104 to 689 kPa of water pressure THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED Consult fixture manufacturer for minimum pressure requirements Most Low Consum...

Страница 4: ...oupling by hand A Lubricate tailpiece o ring with water Insert adjustable tailpiece into control stop Tighten tailpiece coupling by hand Max adjustment of Sloan Adjustable Tailpiece is 13 mm IN or OUT...

Страница 5: ...ODEL 194 ES SM SHOWN 1 25 mm DIAMETER HOLE FINISHED WALL ETF 211 WALL ANCHORS INSTALLED EL 456 GASKET FLAT SIDE TOWARD WALL EL 460 WALL BRACKET OVERRIDE BUTTON MODELS 150 152 SENSOR SCREW ETF 212 6 PH...

Страница 6: ...seconds the start up mode automatically repeats itself when power is restored C The self adaptive sensor is equipped with the sentinel flush feature automatically flushes every twenty four 24 hours a...

Страница 7: ...ake certain that water supply is turned ON and the Control Stop is open CAUSE EL 128 A cartridge is fouled or jammed SOLUTION Turn electronic power to valve OFF failure to do so could result in damage...

Страница 8: ...6 F 21 1 38 mm Double Slip Elbow RB Models 152 ES SM and 190 ES SM 7 F 2 AA 1 38 mm Slip Joint Coupling RB Set of Two Model 152 ES SM 8 F 2A 1 38 mm Slip Joint Coupling RB Model 190 ES SM 9 F 2 AW 19...