background image

NiMH DISCHARGE 
1.3A      

    

CUT: 5.10V 

NiMH/NiCd Battery Program

NiMH/NiCd Battery Program

NiMH/NiCd Discharge Mode:

After  selecting  the  correct  battery  type,  use 
the  INC  or  DEC  button  to  select  the 
“DISCHARGE”  mode.  Press  the  START 
button  and  the  amp  rate  value  will  begin 
flashing.  Use  the  INC  or  DEC  buttons  to 
adjust the value to the desired discharge rate. 
Press  the  START  button  again  and  the 
voltage cut-off will begin to flash. Use the INC 
or  DEC  button  to  adjust  the  value  to  the 
desired rate.
Follow  the  instructions  provided  on  your 
battery  when  setting  the  voltage  cut-off.  The 
B6 V2 will  stop  discharging  when  the  battery 
has reached the preset voltage cut-off.
Press  and  hold  the  START  button  for  3 
seconds  to  start  discharging.  Once 
discharging has commenced, the charger will 
display  the  following  real-time  information: 
battery  type,  discharging  current,  battery 
voltage,  working  mode

elapsed  time  and 

discharged capacity.

When discharging is complete, the screen will 
read  “DONE”  and  the  charger  will  emit  a 
ringing sound.
The charger will display the elapsed time, end 
voltage and the discharged capacity in mAh.
You  can  press  the  STOP  button  at  any  time 
during  the  discharging  process  to  stop  the 
discharge process.

NiMH 

 

    0.6A 

    

5.43V 

DCH

 

             0

0

:02:22

N

iMH DONE        5.10V

DISCHG          00:03:17

NiMH/NiCd Re-Peak Mode:

Applicable  to  NiMH  and  NiCD  batteries  only,  in  re-peak  mode  the 
charger can peak- charge the battery once, twice, or three times in a 
row automatically. This process is good for confirming that the battery 
is fully charged and for verifying how well the battery can accept a fast 
charge.  A  five-minute  cool-down  delay  occurs  after  each  re-peak 
charge.

IN RE-PEAK MODE, THE B6 V2 USES THE CHARGE AMPERAGE 
AND VOLTAGE SETTINGS ENTERED IN CHARGE MODE.

After  selecting  the  correct  battery  type,  use 
the  INC  or  DEC  button  to  select  the  “RE-
PEAK”  mode.  Press  the  START  button  and 
the  Re-peak  cycle  number  1  begins  to  flash 
on the screen. Use the INC or DEC button to 
scroll  through  the  cycle  count  and  set  a 
number between  1 and 3.
Press  and  hold  the  START  button  for  3 
seconds to start  the re-peak process.

Once  the  Re-Peak  process  has  begun,  the 
charger  will  display  the  following  real-time 
information:  battery  type,  charging  current, 
battery  voltage,  elapsed  time  and  charged 
capacity.
Once  the  Re-Peak  process  has  completed, 
the screen will read “DONE” and the charger 
will  emit  a  ringing  sound.  The  charger  will 
display  the  charge/discharge  capacity  for 
each  cycle.  Using  the  +  and  -  buttons,  you 
can  scroll  through  the  history  data  of  each 
cycle.

NiMH RE-PEAK 
2

NiMH     2.0A       6.28V
RPC                00:04:04

START/ENTER

NiMH 

 

    0.6A 

    

5.43V 

DCH

 

   

       

00106

mAh

 

NiMH    2.0A       6.28V
RPC            00686mAh

· 18

B6 V2

19 ·

B6 V2

Содержание IMAX B6 V2

Страница 1: ...attery This charger can be powered by 11 18V DC it is able to power DC equipment such as LED pit light motor checker etc Please BE SURE to read these INSTRUCTIONS WARNING and SAFETY NOTES before you u...

Страница 2: ...expert user only Balancing Individual Cells Battery During Discharging During the process of discharging SKYRC B6 V2 can monitor and balance each cell of the battery individually Error message will b...

Страница 3: ...cell 1 2V cell 1 5V cell n a 1C 2C NiCd 1 2V cell 1 5V cell n a 1C 2C NiMH 2 0V cell 2 46V cell n a 0 4C Pb 0 1 1 1V cell 0 1 1 1V cell 1 8V cell LiHV 3 7V cell 4 35V cell 3 85V cell 1C 3 1 3 4V cell...

Страница 4: ...ks can be wired in parallel and in series i e a 2 cell pack can be 3 7V in parallel or 7 4V in series Have you checked that all connections are firm and secure Make sure there are no intermittent cont...

Страница 5: ...Low Cut Off 11 0V SAVE PROGRAM SAVE ENTER BATT MEMORY 2 NiMH 2 4V 2S BATT MEMORY 2 C 2 0A D 1 0A ENTER 3 Seconds BATT MEMORY 2 ENTER SET BATT MEMORY 3 ENTER SET SAVE PROGRAM SAVE ENTER BATT MEMORY 3...

Страница 6: ...am directly You could change the mode balance mode normal charge mode fast charge mode store mode or discharge mode enter the desired charging discharging mode set the referred parameter and start the...

Страница 7: ...for discharging NiMH NiCd battery This mode is for charging Pb battery in cold days when the temperature is 5 to 20 This mode is for discharging Pb battery NORMAL CHG This mode is for charging Pb bat...

Страница 8: ...nd storing pertinent information for up to 10 different program sets Once a battery program is stored into memory it will be retained until changed again manually Recalling a program memory number mak...

Страница 9: ...HE WARNINGS AND SAFETY INFORMATION CONTAINED ON PAGES 05 07 After selecting the correct battery type if the screen does not read CHARGE use the DEC or INC buttons to change it to the CHARGE mode BEFOR...

Страница 10: ...V DCH 00 02 22 NiMH DONE 5 10V DISCHG 00 03 17 NiMH NiCd Re Peak Mode Applicable to NiMH and NiCD batteries only in re peak mode the charger can peak charge the battery once twice or three times in a...

Страница 11: ...times consecutively Press and hold the START button for 3 seconds to start the Cycle Mode Once cycling has commenced the charger will display the following real time information battery type charging...

Страница 12: ...amp rate should be set to 1 10th of capacity For example if you are charging a 20Ah battery the charge rate should be set to 2A Follow the instructions provided on your battery when setting the amp r...

Страница 13: ...to the desired discharge rate Follow the instructions provided with your battery when setting the amp rate Press the START button again and the nominal battery pack voltage will begin flashing Use th...

Страница 14: ...DIAGRAM Note Mavic charging cable is not included in the package Press the Power Button once Then Press Again and Hold for 2 Seconds to Turn On BATT PROGRAM TOOL KITS DJI DRONE BATT Mavic Charge Mode...

Страница 15: ...NC DEC INC The charger can store up to 10 different charge discharge profiles for your convenience and the stored profiles can be recalled quickly without having to go through the setup process When y...

Страница 16: ...a charge process the integral safety timer automatically starts running at the same time This is programmed to prevent overcharge the battery if it proves to be faulty or if the termination circuit ca...

Страница 17: ...nput Low Cut Off 11 0V 10 12V There will be error message when DC input voltage is lower than the reset value System Setting Battery Voltage Meter STOP STATUS START The user can check battery s total...

Страница 18: ...g and Error Message In case of an error the screen will display the cause of error and emit an audible sound Incorrect polarity connected The battery is interrupted The battery cell you sent is differ...

Страница 19: ...discharge profiles Charge Method CC CV for lithium types and lead Pb batteries Delta peak Sensitivity for NiMH NiCd DC Input Voltage 11 18V Display Type 2x16 LCD Display Backlight Blue Case Material...

Страница 20: ...ection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions...

Страница 21: ...pack by 3 3 A 4 cell LiIo wired in series will have a nominal voltage of 13 2 volts 4x3 3 If the nominal voltage of the battery is not printed on the battery s label consult your battery manufacturer...

Страница 22: ...nge without notice 7504 1239 01 This content is subject to change Latest version can be downloaded from www skyrc com If you have any question about this document please contact SkyRC by sending a mes...

Отзывы: