background image

Commonly Used Terms

Commonly used terms

Final  charge  voltage:

  the  voltage  at  which  the  battery's  charge  limit 

(capacity  limit)  is  reached.  The  charge  process  switches  from  a  high 
current  to  a  low  maintenance  rate  (trickle  charge)  at  this  point.  From 
this  point  on  further  high  current  charging  would  cause  overheating 
and eventual terminal damage to the pack.

Final discharge voltage:

 the voltage at which the battery's discharge 

limit is reached. The chemical composition of the batteries determines 
the level of this voltage. Below this voltage the battery enters the deep 
discharge  zone.  Individual  cells  within  the  pack  may  become  reverse 
polarized in this condition, and this can cause permanent damage.

A,  mA:

  unit  of  measurement  relating  to  charge  or  discharge 

current.1000 mA = 1 A (A=Ampere,mA=Milliampere)

Ah, mAh:

 unit of measurement for the capacity of a battery (Amperes 

x time unit; h = hour). If a pack is charged for one hour at a current of 2 
A,  it  has  been  fed  2  Ah  of  energy.  It  receives  the  same  quantity  of 
charge (2 Ah) if it is charged for 4 hours at 0.5 A, or 15 minutes (=1/4 
h) at 8 A.

'C'-rating: 

Capacity is also referred to as the 'C' rating. Some battery 

suppliers  recommend  charge  and  discharge  currents  based  on  the 
battery  'C'  rating. A  battery's  '1C'  current  is  the  same  number  as  the 
battery's rated capacity number, but noted in mA or amps. A 600mAh 
battery has a 1C current value of 600mA, and a 3C current value of (3 
x  600mA)  1800mA  or  1.8A.  The  1C  current  value  for  a  3200mAh 
battery would be 3200mA (3.2A).

Nominal voltage(V): 

The nominal voltage of the battery pack can be 

determined as follows;
-.NiCd or NiMH: multiply the total number of cells in the pack by 1.2. A 
8-cell pack will have a nominal voltage of 9.6 volts (8x1.2).
-.LiPo:  multiply  the  total  number  of  cells  in  the  pack  by  3.7. A  3-cell 
LiPo wired in series will have a nominal voltage of 11.1 volts (3x3.7).
-.LiIo: multiply the total number of cells in the pack by 3.6. A 2-cell LiIo 
wired in series will have a nominal voltage of 7.2 volts (2x3.6).
-.LiFe: multiply the total number of cells in the pack by 3.3. A 4-cell LiIo 
wired in series will have a nominal voltage of 13.2 volts (4x3.3).
If the nominal voltage of the battery is not printed on the battery's label, 
consult your battery manufacturer or supplier. Do not guess the rated 
voltage of battery.

Warranty and Service

This charger is designed and approved exclusively for use with the types of 
battery stated in this Instruction Manual. SkyRC accepts no liability of any 
kind if the charger is used for any purpose other than that stated.
We are unable to ensure that you follow the instructions supplied with the 
charger,  and  we  have  no  control  over  the  methods  you  employ  for  using, 
operating  and  maintaining  the  device.  For  this  reason  we  are  obliged  to 
deny  all  liability  for  loss,  damage  or  costs  which  are  incurred  due  to  the 
incompetent  or  incorrect  use  and  operation  of  our  products,  or  which  are 
connected with such operation in any way.Unless otherwise prescribed by 
law, our obligation to pay compensation, regardless of the legal argument 
employed,  is  limited  to  the  invoice  value  of  those  SkyRC  products  which 
were  immediately  and  directly  involved  in  the  event  in  which  the  damage 
occurred.

Liability exclusion

Warranty and service

We guarantee this product to be free of manufacturing and assembly defects 
for a period of one year from the time of purchase. The warranty only applies 
to material or operational defects, which are present at the time of purchase. 
During that period, we will repair or replace free of service charge for products 
deemed defective due to those causes.

This warranty is not valid for any damage or subsequent damage arising as a 
result of misuse, modification or as a result of failure to observe the procedures 
outlined in this manual.

The warranty service is valid in China only.
If you need warranty service overseas, please contact your dealer in the 
first  instance,  who  is  responsible  for  processing  guarantee  claims 
overseas.  Due  to  high  shipping  cost,  complicated  custom  clearance 
procedures  to  send  back  to  China.  Please  understand  SkyRC  can't 
provide warranty service to  overseas end user directly.
If  you  have  any  questions  which  are  not  mentioned  in  the  manual, 
please feel free to send email to [email protected]

Note:

1.
2.

3.

· 40

B6 V2

41 ·

B6 V2

Содержание IMAX B6 V2

Страница 1: ...attery This charger can be powered by 11 18V DC it is able to power DC equipment such as LED pit light motor checker etc Please BE SURE to read these INSTRUCTIONS WARNING and SAFETY NOTES before you u...

Страница 2: ...expert user only Balancing Individual Cells Battery During Discharging During the process of discharging SKYRC B6 V2 can monitor and balance each cell of the battery individually Error message will b...

Страница 3: ...cell 1 2V cell 1 5V cell n a 1C 2C NiCd 1 2V cell 1 5V cell n a 1C 2C NiMH 2 0V cell 2 46V cell n a 0 4C Pb 0 1 1 1V cell 0 1 1 1V cell 1 8V cell LiHV 3 7V cell 4 35V cell 3 85V cell 1C 3 1 3 4V cell...

Страница 4: ...ks can be wired in parallel and in series i e a 2 cell pack can be 3 7V in parallel or 7 4V in series Have you checked that all connections are firm and secure Make sure there are no intermittent cont...

Страница 5: ...Low Cut Off 11 0V SAVE PROGRAM SAVE ENTER BATT MEMORY 2 NiMH 2 4V 2S BATT MEMORY 2 C 2 0A D 1 0A ENTER 3 Seconds BATT MEMORY 2 ENTER SET BATT MEMORY 3 ENTER SET SAVE PROGRAM SAVE ENTER BATT MEMORY 3...

Страница 6: ...am directly You could change the mode balance mode normal charge mode fast charge mode store mode or discharge mode enter the desired charging discharging mode set the referred parameter and start the...

Страница 7: ...for discharging NiMH NiCd battery This mode is for charging Pb battery in cold days when the temperature is 5 to 20 This mode is for discharging Pb battery NORMAL CHG This mode is for charging Pb bat...

Страница 8: ...nd storing pertinent information for up to 10 different program sets Once a battery program is stored into memory it will be retained until changed again manually Recalling a program memory number mak...

Страница 9: ...HE WARNINGS AND SAFETY INFORMATION CONTAINED ON PAGES 05 07 After selecting the correct battery type if the screen does not read CHARGE use the DEC or INC buttons to change it to the CHARGE mode BEFOR...

Страница 10: ...V DCH 00 02 22 NiMH DONE 5 10V DISCHG 00 03 17 NiMH NiCd Re Peak Mode Applicable to NiMH and NiCD batteries only in re peak mode the charger can peak charge the battery once twice or three times in a...

Страница 11: ...times consecutively Press and hold the START button for 3 seconds to start the Cycle Mode Once cycling has commenced the charger will display the following real time information battery type charging...

Страница 12: ...amp rate should be set to 1 10th of capacity For example if you are charging a 20Ah battery the charge rate should be set to 2A Follow the instructions provided on your battery when setting the amp r...

Страница 13: ...to the desired discharge rate Follow the instructions provided with your battery when setting the amp rate Press the START button again and the nominal battery pack voltage will begin flashing Use th...

Страница 14: ...DIAGRAM Note Mavic charging cable is not included in the package Press the Power Button once Then Press Again and Hold for 2 Seconds to Turn On BATT PROGRAM TOOL KITS DJI DRONE BATT Mavic Charge Mode...

Страница 15: ...NC DEC INC The charger can store up to 10 different charge discharge profiles for your convenience and the stored profiles can be recalled quickly without having to go through the setup process When y...

Страница 16: ...a charge process the integral safety timer automatically starts running at the same time This is programmed to prevent overcharge the battery if it proves to be faulty or if the termination circuit ca...

Страница 17: ...nput Low Cut Off 11 0V 10 12V There will be error message when DC input voltage is lower than the reset value System Setting Battery Voltage Meter STOP STATUS START The user can check battery s total...

Страница 18: ...g and Error Message In case of an error the screen will display the cause of error and emit an audible sound Incorrect polarity connected The battery is interrupted The battery cell you sent is differ...

Страница 19: ...discharge profiles Charge Method CC CV for lithium types and lead Pb batteries Delta peak Sensitivity for NiMH NiCd DC Input Voltage 11 18V Display Type 2x16 LCD Display Backlight Blue Case Material...

Страница 20: ...ection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions...

Страница 21: ...pack by 3 3 A 4 cell LiIo wired in series will have a nominal voltage of 13 2 volts 4x3 3 If the nominal voltage of the battery is not printed on the battery s label consult your battery manufacturer...

Страница 22: ...nge without notice 7504 1239 01 This content is subject to change Latest version can be downloaded from www skyrc com If you have any question about this document please contact SkyRC by sending a mes...