SECTION 4, Page 12
SJKB-40-D, SJKB-40-D/F
JUN. 1999
TROUBLESHOOTING (Cont.)
TROUBLE
PROBABLE CAUSE
REMEDY
ELECTRICAL SYSTEM (Cont.)
NO TELESCOPE EX-
TEND FROM PLATFORM
CONTROLS
1.
Loose or broken wire #99 from
platform terminal block TB1 to
telescope switch S16.
2.
Defective telescope switch S16.
3.
Loose or broken wire #39 from
telescope switch S16 to platform
terminal block TB2.
4.
Loose or broken wire #39 from
platform terminal block TB2 to
base terminal block TB3.
1.
Check Continuity. Replace if
defective.
2.
Check Switch. Replace if
defective.
3.
Check Continuity. Replace if
defective.
4.
Check Continuity. Replace if
defective.
NO JIB DOWN FROM
PLATFORM AND BASE
CONTROLS
1.
Loose or broken wire #34 from
base terminal block TB3 to relay
34CR.
2.
Loose or broken wire #02 from
relay 34CR to base terminal block
TB3.
3.
Defective relay 34CR.
4.
Loose or broken wire #09 from
base terminal block TB3 to relay
34CR.
5.
Loose or broken wire #34A from
relay 34CR to jib down valve coil
4H-34A.
6.
Defective jib down valve coil 4H-
34A.
7.
Loose or broken wire #02 from jib
down valve 4H-34A to base
terminal block TB3.
8.
Open diode D34.
1.
Check Continuity. Replace if
defective.
2.
Check Continuity. Replace if
defective.
3.
Check Relay. Replace if defective.
4.
Check Continuity. Replace if
defective.
5.
Check Continuity. Replace if
defective.
6.
Check Continuity through coil.
Replace if defective.
7.
Check Continuity. Replace if
defective.
8.
Check Diode. Replace if defective.
NO JIB UP FROM PLAT-
FORM AND BASE CON-
TROLS
1.
Loose or broken wire #35 from
base terminal block TB3 to relay
35CR.
2.
Loose or broken wire #02 from
relay 35CR to base terminal block
TB3.
3.
Defective relay 35CR.
4.
Loose or broken wire #09 from
base terminal block TB3 to relay
35CR.
5.
Loose or broken wire #35A from
relay 35CR to jib down valve coil
4H-35A.
6.
Defective jib down valve coil 4H-
35A.
7.
Loose or broken wire #02 from jib
down valve 4H-35A to base
terminal block TB3.
8.
Open diode D35.
1.
Check Continuity. Replace if
defective.
2.
Check Continuity. Replace if
defective.
3.
Check Relay. Replace if defective.
4.
Check Continuity. Replace if
defective.
5.
Check Continuity. Replace if
defective.
6.
Check Continuity through coil.
Replace if defective.
7.
Check Continuity. Replace if
defective.
8.
Check Diode. Replace if defective.
Содержание SJKB-40-D
Страница 1: ......
Страница 51: ...SJKB 40 D SJKB 40 D F SECTION 3 Page 28 JUNE 1999 NOTES ...
Страница 85: ...SECTION 5 Page 2 SJKB 40 D SJKB 40 D F JUN 1999 NOTES ...
Страница 100: ...SECTION 5 Page 17 SJKB 40 D SJKB 40 D F JUN 1999 NOTES ...
Страница 129: ...SECTION 6 Page 16 SJKB 40 D SJKB 40 D F JUN 1999 NOTES ...
Страница 137: ...SECTION 6 Page 24 SJKB 40 D SJKB 40 D F JUN 1999 NOTES ...
Страница 189: ...SECTION 6 Page 76 SJKB 40 D SJKB 40 D F JUN 1999 NOTES ...
Страница 209: ...SECTION 6 Page 96 SJKB 40 D SJKB 40 D F JUN 1999 NOTES ...