SECTION 4, Page 11
SJKB-40-D, SJKB-40-D/F
JUN. 1999
TROUBLESHOOTING (Cont.)
TROUBLE
PROBABLE CAUSE
REMEDY
ELECTRICAL SYSTEM (Cont.)
NO TELESCOPE RE-
TRACT FROM PLAT-
FORM OR BASE CON-
TROLS
1.
Loose or broken wire #38 from
base terminal block TB3 to relay
38CR.
2.
Loose or broken wire #02 from
relay 38CR to base terminal block
TB3.
3.
Defective relay 38CR.
4.
Loose or broken wire #09 from
base terminal block TB3 to relay
38CR.
5.
Loose or broken wire 38A from
relay 38CR to telescope retract
valve coil 4H-38A.
6.
Defective telescope retract valve
coil 4H-38A.
7.
Loose or broken wire #02 from
telescope retract valve coil 4H-38A
to base terminal block TB3.
8.
Open diode D38.
1.
Check Continuity. Replace if
defective.
2.
Check Continuity. Replace if
defective.
3.
Check Relay. Replace if defective.
4.
Check Continuity. Replace if
defective.
5.
Check Continuity. Replace if
defective.
6.
Check Continuity through coil.
Replace if defective.
7.
Check Continuity. Replace if
defective.
8.
Check Diode. Replace if defective.
NO TELESCOPE EX-
TEND FROM PLATFORM
OR BASE CONTROLS
1.
Loose or broken wire #39 from
base terminal block TB3 to relay
39CR.
2.
Loose or broken wire #02 from
relay 39CR to base terminal block
TB3.
3.
Defective relay 39CR.
4.
Loose or broken wire #09 from
base terminal block TB3 to relay
39CR.
5.
Loose or broken wire 39A from
relay 39CR to telescope retract
valve coil 4H-39A.
6.
Defective telescope retract valve
coil 4H-39A.
7.
Loose or broken wire #02 from
telescope retract valve coil 4H-39A
to base terminal block TB3.
8.
Open diode D39.
1.
Check Continuity. Replace if
defective.
2.
Check Continuity. Replace if
defective.
3.
Check Relay. Replace if defective.
4.
Check Continuity. Replace if
defective.
5.
Check Continuity. Replace if
defective.
6.
Check Continuity through coil.
Replace if defective.
7.
Check Continuity. Replace if
defective.
8.
Check Diode. Replace if defective.
NO TELESCOPE RE-
TRACT FROM PLAT-
FORM CONTROLS
1.
Loose or broken wire #08 from
platform terminal block TB1 to
telescope switch S16.
2.
Defective telescope switch S16.
3.
Loose or broken wire #38 from
telescope switch S16 to platform
terminal block TB2.
4.
Loose or broken wire #38 from
platform terminal block TB2 to
base terminal block TB3.
1.
Check Continuity. Replace if
defective.
2.
Check Switch. Replace if
defective.
3.
Check Continuity. Replace if
defective.
4.
Check Continuity. Replace if
defective.
Содержание SJKB-40-D
Страница 1: ......
Страница 51: ...SJKB 40 D SJKB 40 D F SECTION 3 Page 28 JUNE 1999 NOTES ...
Страница 85: ...SECTION 5 Page 2 SJKB 40 D SJKB 40 D F JUN 1999 NOTES ...
Страница 100: ...SECTION 5 Page 17 SJKB 40 D SJKB 40 D F JUN 1999 NOTES ...