Section 3 - Operation
Start Operation
3.8-9 Electrical Inverter (If Equipped)
1.
Turn main power disconnect switch to “ ”on
position.
2.
Make sure on/off switch of the inverter is “ ”on
position.
3.
Inverter state is indicated by the LEDs on the face
of the inverter. A glowing green LED indicates
normal operation. If a fault occurs, the status LEDs
will indicate the area responsible.
CAUTION
The main power disconnect switch must
be turned off at the end of the shift or the
batteries will drain.
3.8-10 Shutdown Procedure
1.
Completely lower the platform.
2.
On platform control console, push in “
”
emergency stop button.
WARNING
Ensure that you maintain three points of
contact when using the ladder to mount/
dismount platform.
3.
Use the ladder to dismount from platform.
4.
On base control console, select off/platform/base
key switch to “
” off position and remove the key.
5.
Turn main power disconnect switch to “
” off
position.