237
SJ82 T, SJ86 T
229040ABA
Deutz Diesel Engines
Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN
FMI Blink Code
Error Identification
1341
524035
12
5-5-5
Injector diagnostics; time out error in the SPI communication.
1342
524036
12
5-5-5
Injector diagnostics Slave; time out error in the SPI communication.
1345
524069
9
8-9-6
Timeout Error of CAN-Receive-Frame MSMon_FidFCCTO; Master-Slave CAN
communication faulty.
1357
524052
11
8-3-6
Error memory Slave reports FID MSMonFC2 (collective error).
1368
524052
11
8-3-6
Error memory Slave reports FID MSMonFC3 (collective error).
1378
523919
2
6-9-4
Sensor air pump airpressure; plausibility error.
1379
523920
2
7-1-6
Sensor exhaust gas back pressure burner; plausibility error.
1380
3253
2
6-9-2
Sensor differential pressure (DPF); plausibility error.
1381
164
2
8-3-9
Rail pressure safety function is not executed correctly ().
1389
523922
5
7-1-5
Burner Shut Off Valve; open load.
1390
523922
12
7-1-5
Burner Shut Off Valve; powerstage over temperature.
1392
523922
4
7-1-5
Burner Shut Off Valve; short circuit to ground.
1395
523921
2
7-1-4
Burner temperature sensor; Plausibility Check for burner temperature sensor
Sensor burner temperature; plausibility error.
1398
1136
0
6-8-1
Physical range check high for ECU temperature.
1402
4769
2
6-8-4
Sensor exhaust gas temperature OxiCat downstream (normal operation);
plausibility error.
1403
4769
2
6-8-4
Sensor exhaust gas temperature OxiCat downstream (regeneration);
plausibility error.
1411
1188
11
8-1-4
Wastegate actuator; internal error.
1412
1188
11
8-1-4
Wastegate actuator; EOL calibration not performed correctly.
1413
1188
13
8-1-4
Wastegate actuator calibration deviation too large, recalibration required.
1414
1188
2
8-1-4
Wastegate; status message from ECU missing.
1415
1188
7
8-1-4
Wastegate actuator; blocked.
1417
1188
11
8-1-4
Wastegate actuator; over temperature (> 135°C).
1418
1188
11
8-1-4
Wastegate actuator; operating voltage error.
1423
51
0
5-9-4
Warning threshold for an internal actuator error exceeded, < 4L EGR.
actuator und >4L Air Intake Flap.
1424
51
1
5-9-4
Shut off threshold for an internal actuator error exceeded, < 4L EGR.actuator
und >4L Air Intake Flap.
1425
172
0
2-2-6
air temperature within air filter box above maximum physical value.
1431
524028
2
8-1-5
CAN message PROEGRActr; plausibility error.
1432
524029
2
8-1-5
Timeout Error of CAN-Receive-Frame ComEGRActr - exhaust gas
recirculation positioner.
1436
524034
5
8-1-6
Disc separator; open load.
1437
524034
12
8-1-6
Disc separator; powerstage over temperature.
1438
524034
3
8-1-6
Disc separator; short circuit to battery.
1513AA-17
To
order go
to
Discount-Equipment.com