Deutz Diesel Engines
Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN
FMI Blink Code
Error Identification
8
132
1
2-2-6
The air mass flow AFS_dm is greater than or equal to AFS_PhysRng.Min_C.
Physical range check is low for air mass flow sensor.
9
172
2
2-2-6
Air inlet filter temperature, plausibility error.
26
523891
14
2-6-3
When AirHt_ctDefSRCLoOn_mp is lower than AirHt_ctMaxDef_C.
DFC to SRC Low error when heater is on.
28
523953
2
7-2-8
Healing takes place if the condition for error detection is not present.
Air temperature monitoring plausibility check array.
30
523955
2
7-2-8
Healing takes place if the condition for error detection is not present.
Air temperature monitoring plausibility check array.
36
523923
3
7-2-9
37
523924
3
1-6-7
Short circuit to battery error of actuator relay 2.
38
523925
3
7-3-1
Short circuit to battery of actuator relay 3.
40
523927
3
7-3-3
Short circuit to battery of actuator relay 6.
41
523923
4
7-2-9
Short circuit to ground error.
Detailed information not available.
42
523924
4
1-6-7
Short circuit to ground of actuator relay 2.
43
523925
4
7-3-1
Short circuit to ground of actuator relay 3.
44
523926
4
7-3-2
Short circuit to ground of actuator relay 4.
45
168
3
3-1-8
Sensor battery voltage error; signal range check is high.
46
168
4
3-1-8
Sensor battery voltage error; signal range check is low.
47
168
2
3-1-8
High battery voltage; warning threshold is exceeded.
48
168
2
3-1-8
High battery voltage; Shot off threshold exceeded.
55
523910
14
6-9-5
Air pump doesn’t achieve air mass flow setpoint. Burner Control - burner air
pump.
56
524013
7
8-5-6
Burner Control. Burner does not start after several trials (burner flame lost
detection).
Burner flame unintentional deleted.
57
524020
14
8-6-3
Burner Control: Power reduction due to low lambda. Engine power: Not
enough oxygen for regeneration.
58
523911
0
7-2-3
Burner dosing valve (DV2); Overcurrent at the end of the injection phase.
59
523911
12
7-2-3
Burner dosing valve (DV2); Powerstage over temperature.
60
523911
3
7-2-3
Burner dosing valve (DV2); Short circuit to battery.
62
523911
4
7-2-3
Burner dosing valve (DV2); Short circuit to ground.
63
523911
11
7-2-3
Burner dosing valve (DV2); Short circuit high side powerstage.
64
523912
2
7-2-2
Burner dosing valve (DV2) downstream pressure sensor; plausibility error.
66
523912
0
7-2-2
Physical range check high for burner dosing valve (DV2) downstream
pressure; Shut off regeneration.
1513AA-1