231
SJ82 T, SJ86 T
229040ABA
Deutz Diesel Engines
Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN
FMI Blink Code
Error Identification
857
523613
0
1-3-4
Rail pressure metering unit, Rail pressure disrupted. Maximum positive
deviation of rail pressure exceeded.
858
523613
0
1-3-4
Rail pressure metering unit, Rail pressure disrupted. Maximum positive
deviation of rail pressure in metering unit exceeded (RailMeUn1).
859
523613
0
1-3-4
Rail pressure metering unit, Rail pressure below the target range.
(RailMeUn2)
Railsystem leakage detected.(RailMeUn10)
861
523613
1
1-3-4
Rail pressure metering unit, Minimum rail pressure exceeded (RailMeUn3).
Negative deviation of rail pressure second stage (RailMeUn22).
862
523613
0
1-3-4
Rail pressure metering unit, Maximum rail pressure exceeded.
864
523613
2
1-3-4
Rail pressure metering unit, Setpoint of metering unit in overrun mode not
plausible.
865
523613
0
1-3-4
Setpoint of metering unit in overrun mode not plausible.
874
157
0
1-4-7
Rail pressure raw value is intermittent. No detailed information!
875
157
1
1-4-7
rail pressure raw value is above maximum offset. No detailed information!
876
523470
7
1-4-6
Maximum rail pressure exceeded (PRV).
877
157
3
1-4-7
Sensor error rail pressure. Sensor voltage above upper limit.
878
157
4
1-4-7
Sensor error rail pressure. Sensor voltage below lower limit.
881
523633
11
1-4-9
Longterm adaption factor below threshold.
882
523633
11
1-4-9
Nox conversion rate insufficient (SCR-Cat defect, bad DEF quality).
883
523633
11
1-4-9
Nox conversion rate insufficient (SCR-Cat defect, bad DEF quality);
temperature range 1
887
3234
11
1-8-4
DFC for plausibility error Min for NOx sensor downstream of SCR Cat.
889
3224
1
1-8-5
DFC for plausibility error Max for NOx sensor upstream of SCR Cat.
892
4345
11
2-3-6
Sensor backflow line pressure (SCR); plausibility error.
893
4343
11
8-7-1
SCR Monitoring; Pressure stabilisation error, general pressure check error
(SCR).
894
4374
13
8-7-2
Pressure stabilisation error dosing valve (SCR).
897
523632
16
8-7-5
Pump pressure SCR metering unit too high.
898
523632
18
8-7-6
Pump pressure SCR metering unit too low.
899
523632
0
8-7-7
Pressure overload of SCR-System.
900
523632
1
8-7-8
Pressure build-up error SCR-System.
903
4365
0
8-8-1
DEF tank temperature too high.
905
3241
0
8-8-3
Sensor SCR catalyst upstream temperature too high; plausibility error.
908
3361
7
8-8-6
DEF dosing valve blocked (SCR).
914
523720
2
1-4-8
DEF supply module heater temperature; plausibility error (normal condition).
915
523720
2
1-4-8
Sensor DEF supply module heater temperature; plausibility error (cold start
condition).
1513AA-11