January 2019
Page 6
ELECTRICAL HOISTS
Secure cord to Platform so cord weight is on Platform and NOT on connection. At end of work
shift, disconnect power cord from the main outlet. Protect power cords from rain and water at all
times. Ground connector of building receptacle must be grounded.
For 208/220 Volt applications, use one cord in combination with a yoke to the Hoists.
Use a yoke off Platform line with two lengths of 10-3 SOW electric cord.
Normally a 250 ft. 600 Volt 10-3 SOW electric cord is used.
Use a booster transformer when low voltage is encountered.
Electrical Pendant
Part # 41021752 –
(length).
AIR HOISTS
Secure hose to Platform so weight of hose is not on unit. Install two shut off valves – one at air
supply source and one on Platform.
Use a yoke off Platform line with two equal length 3/4 inch hoses.
Hose Inner Diameter (for 100 PSI and 70 CFM / Hoist).
Hose Inner Diameter 3/4"
1”
1-1/4”
One Unit
400 ft.
1000 ft.
1000+ ft.
Two Units - Yoked
100 ft.
300 ft.
1000+ ft.
Filtering and Lubrication
Do not connect to air systems that use synthetic, fire-resistant lubricants – especially phosphate
ester types – in the air compressor.
An air filter and a lubricator are mounted in the input line ahead of the motor. Clean filter elements
periodically.
To service lubricator, remove oil fill plug, fill to visible rim of bowl with SAE No. 10 petroleum
based hydraulic or spindle oil. Do not use oils with adhesive or tacky additives. Replace plug.
Adjust oil flow to about 4 drops per minute. Turn slotted screw in top of lubricator
clockwise
for a
leaner mix, or
counterclockwise
for a richer mix.
Air Pendant
Part # 41021753 –
(length).
WARNING
Do not use an electric hoist in an explosive environment.
!
Содержание Compact 1000
Страница 22: ...January 2019 Page 22 GAST AIR MOTOR COMPACT SERIES HOISTS ...
Страница 23: ...January 2019 Page 23 ...
Страница 24: ...January 2019 Page 24 ...
Страница 25: ...January 2019 Page 25 ...