CHECK DAILY or before the start of each shift:
Permanent Davits – Daily Check
Make sure davit has been inspected and tested prior to use
Make sure davit is installed per manufacturer’s instructions
Make sure capacity is equal to or greater than hoist capacity
Check fist grip torque (if used)
Counterweights – Daily Check
Must be designed for use as counterweight
Make sure they are securely attached to beam
Make sure they are made from a non-flammable material
Make sure they are labeled individually. Sky Climber counterweights are 50 lbs.
Ascertain that:
Instructions are kept with the unit at all times. Additional copies are available – contact Sky Climber.
All Warning and Rating labels are in place, legible, and have been read.
Hoist Drain Holes on the bottom are open. Fasteners checked.
Suspended Platform Hoist is connected to proper power source.
Minimum of 3 J-Clamps are used and are tight. (4 J-Clamps are required for round thimbles).
Cornice Hook, Parapet Clamps or Outriggers, and similar rigging are secured and tied back. Chokers
or similar devices are securely in place. Tie backs are tight and straight back.
Counterweights are non-flowable type, secure, and correct amount.
Roof rigging load is spread using 3/4 inch plywood. Hardwood used for Load Spreader with Parapet.
Wire rope inspected and is not kinked, bird-caged, or otherwise damaged.
The wire rope bitter end is looped and secured with a J-Clamp.
Sky Lock, Hoist Load, Controlled Descent, and Emergency Stop tests performed and acceptable.
!
WARNING
Do NOT use Sky Climber Hoists, Sky Locks, or any equipment
that is damaged or worn beyond normal tolerances.