When two stepless fans are used, they can be set up to work in
parallel or sequentially.
12.1.1.2 Setting of heating
Pre runtime
Time from the heating relay is picked up until heating is physically supplied (flush
time)
Adjust heaters 0-10V
Heater min. voltage
At heating requirement, the analogue voltage will never be lower than
Minimum
voltage.
Heater max. voltage
The heating shunt works at maximum output at this voltage
12.1.2 Network settings
The management program FarmOnline Explorer has access to the house controllers through the network of the
farm.
If a DHCP server is not available in the network, the names of the individual units integrated in the network are
laid down in a plan, and an IP address is assigned to each unit. All names and IP addresses must be unique.
Thus, the entire network must be described in a plan, so it is possible to distinguish between the individual
house controllers. See also the FarmOnline Explorer Technical Manual.
Select the menu
Technical | Service | Network settings| IP- configuration
MAC address
MAC address of the controller. It is, for example, used in connection with error tracing
in the network.
IP configuration mode
DHCP or Static IP.
IP address
The IP address of the controller: e.g. 192.168.1.101.
Net mask
The Netmask of the controller: e.g. 255.255.255.0.
Gateway IP address
The Gateway address of the controller: e.g. 192.168.1.1.
Edit
IP configuration mode
: Selecting Static IP / DHCP
Entering IP address, Netmask and Gateway IP address.
Netmask and gateway must only be set when selecting Static IP.
The house controller is set to Static IP by default.
SKOV A/S recommends that you follow a standard network setup (also see FarmOn-
line Explorer Technical manual).