DOL 834 CE
20
Technical User Guide
4 Climate
4.1 Central air intake
The central air intake function is used to adjust the temperature of the fresh air before it enters the house. The
air is taken into an air mixing room where it may be heated up.
DOL 834 CE
Central air intake
with heating
Temperature control
Figure 3: House with central air intake from air mixing room for adjusting the temperature of outdoor air
Press
Central air intake | Temperature
Air intake setpoint
Setting for the inside temperature that activates the ventilation.
To increase the
Air intake setpoint
without increasing the heating temperature,
you must adjust
Heating setpoint
with the corresponding number of degrees after
you have adjusted the
Air intake setpoint
.
Heating setpoint
Setting for the inside temperature that activates the heating.
It is set as an absolute temperature but also functions as an offset for the
Air in-
take setpoint
. It means that the
Heating setpoint
changes accordingly when the
Air intake setpoint is adjusted.
Outside temperature
Display of the current outside temperature.
Air intake temperature
Display of the temperature at which air inlets are regulated.
Air intake sensor 1
View of the current temperatures of the individual sensors.
Up to four temperature sensors can be connected. The controller will regulate the
temperature in relation to an average of their registrations.
Press
Central air intake | Heating
Heating active
Connection and disconnection of heat supply.
Heating requirement
Current heat supply for the installed heat sources.
Heater 1 requirement
Current heat supply for the individual heater.
Press
Central air intake | Inlet
Ventilation requirement
Displays the current ventilation requirement.
Inlet position
View of how much the air inlet is open.