Lamp and Fuse Replacement
Lamp Replacement
WARNING:
Before attempting to remove the lamp, make sure
the stroboscope is turned off and any mains cords
are removed from the AC outlet. Allow at least five
minutes for the lamp to cool.
The stroboscope is designed to discharge the internal
high voltages within 30 seconds. However, caution
should be exercised when replacing the lamp.
The lamp can be replaced by using just a pocket
screwdriver. It is not necessary to remove any screws
to replace the lamp.
To change the lamp:
•
Push apart the two tabs on the side of the
reflector housing and remove the lens using a
small screwdriver to help pry one tab and lift the
lens. Take care not to pry the tab any more
than is necessary to free the lens. The reflector
is held in place by the front lens and will come
loose, but it is not necessary to remove the
reflector.
•
Hold the lamp with a cloth between your
forefinger and thumb and rock it back and forth
gently while pulling out. Do not attempt to
rotate the lamp. The lamp is socketed and will
come out easily when pulled straight out.