C B
E
6
5
A
1 2
D
G
G
F
3
4
213--- 40/1
13---21
Fuel System
Stanadyne---distributor pump
1. Type plate with pump order number
2. Timing marks under the cover
3. Fuel inlet
4. Return fuel/overflow valve
5. Revolution lever
6. Connector for wire to electric stop solenoid
Eventual injector pump equipment (e.g. E--engines)
A. Interrupted screw (order no 8366 59038)
B. Timing sensor
C. Fuel Limiter
FL
The fuel limiter FL restricts the injection mostly at low
RPM as the air ratio otherwise would be too low.
D. Light Load Advance
LLA
Adjustment of the injection advance according to the ro-
tating speed and load steered by the fuel delivery pres-
sure after the metering valve.
E. Aneroid Control
AC
The aneroid control regulates fuel delivery to match
turbocharger air flow characteristics at low speeds to
minimize smoke during acceleration on low speed.
F. Boost pressure
G. Compact Cold Advance
CCA
Electrical device for earlier injection advance at start and
low load (under 1100 RPM) to minimize the so called cold
smoke. The device includes an injector pump solenoid
and a separate control unit to follow the engine rotating
speed.