Electrical System
15---9
D. Installation of magnetic pick up
1. Rotate the flywheel to a position so that one of the flywheel
ring gears teeth are in front of the pick up installation hole.
0,75
215--- 8
2.Turn the pick up in, until it comes in contact with the tooth.
3.Turn the pick up out ½ turn and tighten the lock nut. This way
the pick up end is
0,75 mm
from the tooth.
Note!
Clean the pick up end from dirt in the yearly service.
E. Temperature sensor
2
1
215--- 9
1. Connection for warning light
2. Connection for temperature gauge
Gauge monitoring resistances:
60
˚
C
134 ± 13,5 ohm
. . . . . . . . . . .
90
˚
C
51,2 ± 4,3 ohm
. . . . . . . . . . .
100
˚
C
38,5 ± 3,0 ohm
. . . . . . . . . . .
Part no.
Alarming tem-
perature
6542 71208
98±3
˚
C
8366 40772
106±3
˚
C
8366 64017
110±3
˚
C