37
|
P a g e
Archimede Portable Dataloggers User Manual
rev.5 -03.12.2019-
In the following pages, the DL will ask which test should be used as a reference test. We suggest to
select the first test in the list (labeled 00). Therefore, it is possible to select any test from the list or
to click the
No reference
button to perform an absolute test.
The values of the reference test will be displayed during the performance of the next test. They
will also be used for graphs elaboration.
The above mentioned page will not be shown in the spiralometer test, since it is not possible to
choose the reference test.
At this point, all the parameters for the data performance have been configured. The DL will ask
which run to do firstly. The number and the type of the runs depend from the type of test:
A1B1/A3B3
An A1B1 run is performed, then the probe is extracted and rotated of
180º and an A3B3 run is performed.
A2B2/A4B4
An A2B2 run is performed, then the probe is extracted and rotated of
180º and an A4B4 run is performed.
A1B1/A2B2/A3B3/A4B4
Runs A1B1, A2B2, A3B3 and A4B4 are performed in sequence;
between each run and the next the probe is extracted and rotated 90º.
Spiralometer
A
head to bottom
run is performed; normally a second
bottom to
head
run is performed.
TREX
A
bottom to head
run is performed first; sometimes a second
head to
bottom
run is performed next.
These sequences are those normally performed. Anyway, you could choose to perform runs in the