P67
操作盤 ∼ MAIN 電路板通信異常
Communication error between panel and MAIN
circuit board
MAIN 電路板 ∼ SDC 電路板通信異常
Communication error between panel and SDC
MAIN 電路板過熱
MAIN circuit board overheat
MAIN 記憶體寫入不良
MAIN memory write-in trouble
INT 記憶體寫入不良
INT memory write-in trouble
電源異常
插頭脫落
Abnormal power source
Disconnection of connector
操作盤 ∼ MAIN 電路板不能通信
Communication between the panel and MAIN
circuit board cannot be performed
MAIN 電路板 ∼ SDC 電路板不能通信
Communication between MAIN circuit board and
SDC cannot be performed
MAIN 電路板過熱
Overheat of MAIN circuit board
MAIN 電路板不能寫入
Memory write-in of MAIN circuit board cannot
be performed.
機頭電路板記憶體不能寫入
Memory write-in of the head circuit board cannot
be performed.
電源電壓規格不對
插頭脫落
Power source voltage type is different.
The connector is disconnected.
關閉 (OFF) 電源開關,確認 MAIN 電路板 CN34
是否鬆動
Turn OFF the power switch and check whether CN34
of MAIN circuit board is loose.
關閉 (OFF) 電源開關,確認 MAIN 電路板CN32、SDC
電路板 CN15 是否鬆動、脫落
Turn OFF the power switch and check whether CN32 of
MAIN circuit board or CN15 of SDC circuit board is
disconnected or loose.
關閉(OFF)電源,稍待一些時間後再次打開(ON)
電源。
Turn OFF the power switch and turn ON the power
switch again after some time.
關閉 (OFF) 電源開關,確認 MAIN 電路板
U22 的 ROM 是否鬆動。
Turn OFF the power switch and check the insertion of
ROM of U22 of MAIN circuit board.
關閉 (OFF) 電源開關,確認 MAIN 電路板CN38
是否鬆動、脫落。
Turn OFF the power switch and check whether CN38 of
MAIN circuit board is disconnected or loose.
關閉 (OFF) 電源開關,確認電源電壓和 INT 電路板
CN3、SDC 電路板 CN13 是否鬆動、脫落。
Turn OFF the power switch and check the power source
voltage and check whether CN3 of FLT circuit board or
CN13 of SDC circuit board is disconnected or loose.
(無顯示)
(Without indication)
顯示
Indication
異常名稱
Name of error
異常內容
Description of error
解除方法
Corrective measure
備考
Remarks