10
Hole-in-the-wall installations
Where the appliance is to be installed as a hole-in-the-wall fireplace, a hearth as previously detailed for
floor level fireplaces shall be fitted on the floor beneath the hole so as to
protect combustible material from heat.
However, if a hearth is not to be used, so as to maintain a minimal and contemporary look, the appliance
must be installed so that every part of any naked flame or incandescent part of the fire bed is at least
300mm vertically above any carpet or floor covering.
When no hearth is to be fitted consideration must be given to fixing a tactile barrier to protect young
children, the elderly and the infirm.
A tactile barrier can be in the form of a fender, kerb, hearth, shelf or horizontal bar all made from non-
combustible material and fixed not less than 50mm & not more than 1000mm above the floor level. They
should be positioned not less than 300mm in front of the appliance.
Eco 4
MM
A
Height
555-580mm
B
Width
355-470mm
C
Depth
122
D
Minimum Hearth Depth in Front of the Fire 300mm
E
Heath must Extend Minimum of
150mm
F
Minimum Hearth Height
50mm
E
C
D
A
B
F
Diagram 1