14
The tray is now free and may be lifted away from the box, lift free of the retaining
clips on each side of the burner tray.
Carefully remove the spark generator from the box or remove the cables to the
generator, making a note of which cable goes where.
SECTION 7.1: PREPARING THE OPENING
Before installing the fire, check the flue for correct operation using a smoke pellet, all of the smoke should
be drawn up the flue and exit correctly from the terminal.
If problems are found
DO NOT
fit the fire until corrective measures have been completed.
Protect the decorative hearth whilst pushing the convector box in and out of the opening. Part of the
packaging or a dust sheet can be used.
Before running the gas supply into the opening, offer up the convector box to the fireplace to check the fit
is good.
Ensure that it slides in correctly, the sealing face sits flat and square to the wall or back panel, and that the
base level with the hearth as no leaks are permissible here.
At this stage it is essential to ensure that the spigot outlet of the fire is not obstructed in any way.
Remove the fire box and apply the self-adhesive sealing strips around the edge of the rear of the firebox
frame, approximately 5mm in from the edge.
CABLE FIXING:
Using the template provided, place this within the opening with the bottom edge of the template level with
the hearth.
Содержание Eco4 E4 HE Plus
Страница 32: ...32 Eco 4 HE Manual Control B10 ...