21
Finally place the two small coals E between the
A
coals at the front on either side and coals
B
.
Section 9: COMMISSIONING THE APPLIANCE
Turn on and test the gas supply up to the fire for any leaks, in accordance with current
Approved Codes of Practice (ACOPs)
Section 10: OPERATING THE APPLIANCE
(See Section 18 Users Instruction)
Section 10.2: SPARK FAILURE
The gap between the spark electrode and the pilot should be 3.5 - 4.5mm to produce a good
spark. There should be no need to adjust this.
If under any circumstances the electric spark fails, the pilot may be lit manually by
proceeding with the ignition sequence as previously described, and after turning the control
knob through the spark position, the knob should be held in and the pilot lit with a taper.
Note: Please ensure that the electrode spark igniters’ gap on the manual version
has not been misaligned during the handling of the burner in this installation the
gap should be 5mm from the burner.
Содержание Eco3
Страница 16: ...16 products will have been tested with the appliance although other fire front frets will be compatible ...
Страница 20: ...20 Place the final two A coals between coals D ...
Страница 32: ...32 SECTION 20 LIST OF SPARES Eco 3 Manual Control 13 14B 11B 6B 1B 7B 8B 9B 10B 2B 15B ...
Страница 33: ...33 Eco3 Ceramics A1 A2 A3 A8 A7 A6 A5 A4 ...
Страница 34: ...34 Eco3 Ceramics 9A 10A ...