background image

 

14 

 

 

 
 

 

 
 

 
 

 

 
 

 
 

 
 

 

 
Place the front row of 5 coals/pebbles between the front coal support and the rear matrix as 

shown.  

 

 

 
Now Place the second row as shown below, coals may be rotated slightly within their positions 

to give a good visual effect. 
 

Note: Please ensure that there is a gap 
between the back of the front matrix 
and the pilot assembly where 
applicable, this is to ensure correct 
operating of the pilot and O.D.S system, 
this must not be touching the assembly 
as this will cause the fire to operate 
incorrectly and cause damage to the 
fire and to malfunction.

 

BURNER 

FRONT MATRIX 

PILOT ASSEMBLY 

Содержание Eco3

Страница 1: ... Westerly Verto Installation and User Instructions Please ensure you read both the Fire and the Fascia instructions before starting the installation All instructions must be handed to user for safekeeping This is not a DIY product and must be installed by a Gas Safe registered installer Edition J 09 15 Country s of destination GB IE Eco3 MkIII ...

Страница 2: ...Installation Requirements The appliance must be installed by a competent person in accordance with the Gas Safety Installation and Use Regulations 1998 A Gas Safety Registered installer must be used for this purpose Read all these instructions before any installation takes place and in conjunction with the appliance on site This appliance must be installed in accordance with the rules in force and...

Страница 3: ... lifted from the outer carton Check that the components supplied correlate with the component checklist below If for some reason any of the listed components are missing or damaged do NOT commence with this installation in doing so will invalidate your warranty Please dispose of all the packaging materials at your local recycling centre CONTENT CHECK LIST Quantity Description 1 Burner Tray 1 Fire ...

Страница 4: ...ng the Burner Tray 12 8 Fuel Bed 13 21 9 Commissioning the Appliance 21 10 Operating the Appliance Manual Control 21 10 1 Operating the Appliance Remote Control 21 10 2 Spark Failure 21 11 Setting Pressure 22 12 Spillage Monitoring System 22 23 13 Testing for Spillage 23 14 Briefing the Customer 24 15 Servicing 25 16 Cleaning the Coals 6 17 Troubleshooting Guide 26 27 18 User Instructions 28 30 19...

Страница 5: ...sued by the Scottish Development Department BS 1251 BS 4543 part2 BS 5440 parts 1 2 BS 5871 part 3 BS 6461 parts 1 2 BS 6891 BS 8303 Failure to comply with these regulations could lead to prosecution and deem the warranty Invalid This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult all instructions before installation and u...

Страница 6: ...s as measured from the hearth to the top of the flue Any flue damper plates or restrictors must be removed and no other restriction fitted to the flue Where removal is not practical the restriction must be fixed in the fully open position The flue must be connected to only one fireplace and the flue must not vent more than one appliance There must be no opening in the flue apart from the one that ...

Страница 7: ...6 mbar Gas Inlet connection 8mm Compression 8mm Compression Overall Height N A N A Overall Width 382 382 Overall Depth 196 196 Recess back width 265 265 Tray Height 210 210 Recess Depth 171 171 Air Vent N A N A Injector STEREOMATIC 480 STEROMATIC 190 Valve CPMM 18700 357 CPMM 18700 357 Manual Pilot Assembly Thermocouple Thermocouple T100 1332 250 Thermocouple T100 1332 250 ...

Страница 8: ...tion of the Flame Safety Device FSD may occur Spillage detected during commissioning is almost always a result of poor flue performance that cannot be corrected by any amount of ventilation For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force Section 5 SITE REQUIREMENTS The fireplace opening should be inspected and repairs made where necessary A c...

Страница 9: ...r or scorch SECTION 5 1 PREFABRICATED FLUE BOXES This appliance can be fitted into a number of flue boxes provided that the minimum dimensions required for the appliance complied with The frame of the fire any back panel or other infill panels and the flue box must be sealed together so that there is no possibility of leakage between them The correct clearances to combustible materials i e false c...

Страница 10: ...ly is isolated before commencing installation of the appliance The fireplace opening and environment must be in compliance with specifications laid down in the appropriate sections of these instructions Remove the appliance from its carton as described previously and stand on a dust sheet Place the coals ceramics and fixings safely to one side Remove the burner from the assembly by removing the tw...

Страница 11: ...e pellet all of the smoke should be drawn up the flue and exit correctly from the terminal If problems are found DO NOT fit the fire until corrective measures have been completed Protect the decorative hearth whilst aligning the tray within the opening Part of the packaging or a dust sheet can be used Before running the gas supply into the opening offer up the base plate to the fireplace to check ...

Страница 12: ... base plate making sure that the side lugs locate properly on to the side of the plate Fit the two securing screws through the front plate ensuring that the plate is in front of the front edge of the base plate Connect the gas supply and tighten the gas connections Note Please ensure that the electrode spark igniters gap on the manual version has not been misaligned during the handling of the burn...

Страница 13: ...ing that the rear matrix is sitting behind the two fixed brackets the back of the matrix rests against the rear of the base plate Place front matrix coal support into brackets fitted Note Please ensure that the support brackets are level and that there is a minimum 5mm gap between the burner and the bottom of the rear matrix this must not be touching the burner as this will cause the fire to burn ...

Страница 14: ...itions to give a good visual effect Note Please ensure that there is a gap between the back of the front matrix and the pilot assembly where applicable this is to ensure correct operating of the pilot and O D S system this must not be touching the assembly as this will cause the fire to operate incorrectly and cause damage to the fire and to malfunction BURNER FRONT MATRIX PILOT ASSEMBLY ...

Страница 15: ...ed into the holes in the matrix a well laid out generously spaced coal layout will give the best results Place the fire front fret into position in front of the fire and slide the ashpan door into place The fire front fret shown in these instructions may differ from the one supplied with the appliance we strongly recommend you use a fire front fret supplied by Sirocco fires as these ...

Страница 16: ...16 products will have been tested with the appliance although other fire front frets will be compatible ...

Страница 17: ...17 Traditional Random coal bed option First identify the parts please see below RANDOM COAL FRONT MATRIX 7 X COAL A 3 X COAL B 2 X COAL C 2 X COAL D 2 X COAL E ...

Страница 18: ...t does not touch the pilot assembly behind Place 5 A Coals between the front matrix and the rear matrix as shown do not block the area between the coal supports Place the three large coals B as shown again ensuring that the area between the coal supports is clear ...

Страница 19: ...19 Place the two coals C in the spaces left between Coals B Now place the coals D in the top corners as shown below ...

Страница 20: ...20 Place the final two A coals between coals D ...

Страница 21: ...spark electrode and the pilot should be 3 5 4 5mm to produce a good spark There should be no need to adjust this If under any circumstances the electric spark fails the pilot may be lit manually by proceeding with the ignition sequence as previously described and after turning the control knob through the spark position the knob should be held in and the pilot lit with a taper Note Please ensure t...

Страница 22: ... if the gas has stopped flowing the Flame Supervision Device FSD is operating correctly Always check that the gas has stopped flowing even if you hear the FSD valve close within the 3 minute period Turn OFF the appliance and the gas supply and refit the pressure test point sealing screw SECTION 12 FLUE SPILLAGE MONITORING SYSTEM Remote controlled fires are fitted with a flue spillage safety device...

Страница 23: ... purpose by the appliance manufacturer If the fire is not spilling then further guidance should be sought using the Troubleshooting section as a guide SECTION 13 TESTING FOR SPILLAGE Close all doors and windows to the room containing the appliance Let the fire run on HIGH for five minutes Take a smoke match light it and using a smoke match tube hold it at the top edge of the fire opening 25mm down...

Страница 24: ... care not to use excessive pressure Scratched and other superficial damage to the matt black paintwork of the appliance can be covered with matching heatproof spray Use only the manufacturers recommended spray paint Paint only when the fire is OFF and cold Always mask off the surrounding area to prevent contamination with overspray Ventilate the room during the use of the spray DO NOT attempt to s...

Страница 25: ...ct the gas supply to the appliance and disconnect the isolation tap 7 Check the fireplace opening for rubble accumulation and remove if debris is excessive initiate remedial work on the flue 8 Check the flue with smoke pellet for correct operation 9 Strip off the burner pipes and clean thoroughly 10 Clean out the injector pilot assembly and burner tube DO NOT remove the pilot injector 11 Re assemb...

Страница 26: ...t pilot Fire runs for a time and then cuts off No gas to fire check isolating valves are open Pipe work blockage clean out Air not fully purged re purge supply or wait longer Spark earthing to metal work reset gap correctly Blocked pilot clean out internally Severe restriction in gas supply clear obstruction Faulty thermocouple replace pilot unit Hold control knob in for longer Run through lightin...

Страница 27: ...y open Check meter pressure is adequate Air leak under base of firebox rectify Lint in pilot aeration hole clean thoroughly internally Firebox grommet seal missing rectify Newness smell from brand new appliance Spillage occurring call installer to carry out spillage test and rectify any problems Low temperature sealants or combustible materials used in incorrect positions Air leak under base of fi...

Страница 28: ...lose to the fire See relevant section for further details on clearances to combustibles No combustible material or flooring should protrude onto the hearth DO NOT burn any foreign material on this fire the coals must be of the correct type and lay out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to sooting Before the appliance is inst...

Страница 29: ... the spark click to the PILOT light position ensuring that the control knob is depressed and the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten to fifteen seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition...

Страница 30: ...S AND CERAMICS See the relevant section in the Installation Guide of these instructions SERVICING The fire and flue should be checked on an annual basis to ensure all of the products of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depend on usage but MUST be carried out at least once annually Servicing must be carried out by a compe...

Страница 31: ...ostly dealt with in the installation instructions DO NOT USE YOUR APPLIANCE and in the first instance contact your installer to investigate these further to establish their cause before contacting Sirocco CONTACTING SIROCCO FOR WARRANTY SERVICE OR TO PURCHASE SPARE PARTS In the event of a service or parts claim please note that some parts such as ceramics batteries trims and fronts etc are categor...

Страница 32: ...32 SECTION 20 LIST OF SPARES Eco 3 Manual Control 13 14B 11B 6B 1B 7B 8B 9B 10B 2B 15B ...

Страница 33: ...33 Eco3 Ceramics A1 A2 A3 A8 A7 A6 A5 A4 ...

Страница 34: ...34 Eco3 Ceramics 9A 10A ...

Страница 35: ...RT FIX FK E1 5 0 SI 0 INSTALLATION USER MANUAL ALL MODELS PRT DOC IM ECO 1 SI 1M 6B CONTROL VALVE KNOB PACK X 2 PRT VAL KN UNI 0 MUL 15 7B CONTROL VALVE NATURAL GAS PRT VAL CV ECO NG CO M 8B CONTROL VALVE LPG GAS PRT VAL CV ECO LP CO M 9B INJECTOR NATURAL GAS PRT VAL IJ E1 2 3 A MUL NG 10B INJECTOR LPG GAS PRT VAL IJ E1 2 3 LP MUL LP 11B BURNER NATURAL GAS PRT VAL BR E1 3 NG AE 41M BURNER LPG GAS ...

Страница 36: ... Delta Ltd Lodestar Delta Ltd T A Sirocco Unit 1 11 Weir St Blackburn Lancashire BB2 2AN SIROCCO HEAD OFFICE Telephone number for all departments 0843 289 4268 charged at BT national rate Mon to Fri 10 00 to 15 00 Contact us by email adminuk siroccofire pl View our latest products and use our on line services www siroccofires com Nad Lasem 8 Zabia Wola 96 321 Zelechow Poland WARRANTY AND SERVICE F...

Страница 37: ...tering you will assist us in identifying the correct parts you may require in the future or ensuring that the correct parts are given to an engineer for a service visit Please ensure you provide this to us within 28 days stated and include the Gas Safe notification number or your warranty will not be valid Regular Servicing It is essential that your Sirocco appliance is serviced by a suitably qual...

Страница 38: ...elated costs expenses arising from defective parts repair replacement or otherwise of same will not be covered by this guarantee nor shall the company assume responsibility for same Furthermore the company will not be responsible for any incidental indirect or consequential damages except as provided by law All other guarantees expressed or implied with respect to the product it s components and a...

Отзывы: