![Sintrol Dumo Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/sintrol/dumo-series/dumo-series_user-manual_1283278019.webp)
©2021 Sintrol.
All rights reserved.
19 (104)
Revision 4
①
Mounting bracket
④
2× Set screws, Dog Point M5
②
2× DIN rail holders (optional)
⑤
2× Hex nuts M5
③
8× Screws, ISO 7045 M3 (optional)
⑥
2× WDS Tommy Bar Screws
Mounting arm
Part number: MC901167
The flexible mounting arm allows the device to be installed in various angles and orientations. It also
makes repositioning the device easy and leaves the terminal cover exposed, so it is possible to access the
main board and make configuration changes locally.
Figure 13: Mounting arm
The arm has two adjustable joints that can also be rotated around their center axis. The device enclosure
has built-in holes on the bottom side, where the mounting arm can be attached in 90° steps.
Probe coating
The sensor probe can be equipped with a protective Teflon coating that is suitable for wet conditions in
non-hazardous areas.
Magnetic switch
If magnetic switches are enabled on your device, you can use a magnetic key to initiate Auto Setup
procedure or change the response mode of the device without having to access the main board.
Wireless communication
A standard device communicates with a monitoring system or PC with signals that are transmitted
through physical wires. The device can be equipped with a radio frequency (RF) antenna to enable
wireless communication.