24
Function
Code
Name
Default
Property
Setting
Range
○
○
Group F02 Motor Parameters
0.0~60.0s
Start delay time
F01.21
0.0s
0.0~100.0s
Delay time
of the stop speed
F01.22
0.0s
Model
dependent
○
20.0%~120.0%
Overload protection
coefficient
F02.10
100.0%
◎
0: No protection
1:
2:Variable frequency motor protection
General Motor protection
Overload
protection
selection
F02.09
1
○
0.2~30.0A
Motor no-load
current
F02.08
○
0.001~65.535Ω
Motor stator
resistance
F02.07
Model
dependent
◎
1~36000rpm
Motor rated
rotational speed
F02.06
Model
dependent
◎
0.01Hz~F00.03 (max frequency)
Motor rated
frequency
F02.05
50.00Hz
◎
0.8~1000.0A
Motor rated
current
F02.04
Model
dependent
◎
0~1200V
Motor rated
voltage
F02.03
Model
dependent
◎
0.1~100.0kW
Motor rated power
F02.02
Model
dependent
◎
Motor type
F02.01
0
0: General asynchronous motor (With
low frequency compensation)
1: AC drive asynchronous motor
(without low frequency compensation)
●
0
Reserve
F02.00
0
Group F03 V/F Control
◎
○
○
○
V/F curve setting
0
0.0% (Automatic); 0.1%~20.0%
Torque boost
0.0%
0.0~50.0% (Relative to motor
rated frequency)
20.0%
0.00Hz~F03.05
V/F frequency
point 1
00.00Hz
F03.00
F03.01
F03.02
F03.03
Torque boost
close
0: Linear V/F curve
1: Multiple-point V/F curve
2: 1.3 power low torque V/F curve
3: 1.7 power low torque V/F curve
4: 2.0 power low torque V/F curve
th
th
th
Function Parameters Table