Function
Code
Name
Default
Property
Setting
Range
Combination mode
of the setting
Running direction
0
○
○
50.00Hz
Model
dependent
○
Model
dependent
○
0
○
○
0
◎
○
◎
0
Model
dependent
Model
dependent
0: A
1: B
2: (A+B)
3: (A-B)
4: Max. (A, B)
5: Min. (A, B)
0.00 Hz~F00.03 (max.
frequency
)
0.0~3600.0s
0.0~3600.0s
0: Default direction
1: Reverse direction
2: Prohibit reverse running
2.0kHz~10.0kHz
0: No operation
1: Restore default value
2: Cancel the fault record
2.0kHz~F00.15
0: None
1: Stator resi No-load
current
auto-tuning
2
:
No-load current auto-tuning
F00.10
F00.11
Keypad set
frequency
Acceleration
time 1
F00.12
Deceleration
time 1
F00.13
F00.14
High frequency
carrier setting
F00.15
Function
restore
parameter
F00.18
Low frequency
carrier setting
F00.16
F00.17
Motor parameter
auto-tuning
Group F01 Start-up and Stop Control
0.00~50.00Hz
0.0~100.0s
0.0~150.0%
0.0~100.0s
0
◎
0.50Hz
◎
0.0s
◎
0.0%
0.0s
◎
◎
0: Start-up directly
1: Start-up after DC braking
Start running
mode
F01.00
F01.01
F01.02
F01.03
F01.04
Starting
frequency of
direct start
Retention time of
the starting
frequency
Braking current
before starting
Braking time
before starting
Function Parameters Table