Function
Code
Name
Default
Property
Setting
Range
Stopping frequency
◎
○
○
○
○
◎
●
○
◎
◎
○
○
○
◎
○
0
0
0.00Hz
0.0s
0.0%
0.0s
0.0s
1.00Hz
0
0
0
0.5s
0
0
0.0s
0: Line
1: Reserve
0: Decelerate to stop
1: Coast to stop
0.00~F00.03 (Max.
frequency
)
0.0~50.0s
0.0~150.0%
0.0~50.0s
0.0~3600.0s
0.00~50.00Hz
0
0: The terminal running command is
invalid when powering on
1: The terminal running command is
valid when powering on
0: Shift after zero frequency
1: Shift after starting
frequency
2: Shift after
stopping
speed and
delay time (delay time is set by
F01.22)
0.0~100.0s
0: Disable
1: Enable
0: Run at lower limit frequency
1: Stop
2: Zero speed operation
0.0~3600.0s (F01.17 = 2 is valid)
ACC and DEC
mode selection
F01.05
Stop mode
selection
F01.06
Startingfrequency
of stop braking
F01.07
F01.08
F01.09
Waiting time
of stop braking
Stop DC
braking current
Stop DC
braking time
F01.10
Dead time of
FWD/REV rotation
F01.11
F01.13
Reserve
Terminal running
protection
selection when
powering on
F01.15
F01.16
Shift mode of
FWD/REV rotation
F01.12
Detection time
of stop
frequency
F01.14
Restart
after power off
F01.19
Action if
frequency
> 0)
running
frequency <
lower
limit (Valid:
F01.17
Hibernation restore
delay Time
F01.18
0.0~3600.0s (F01.19=1 is valid)
F01.20
1.0s
○
Waiting time of
restart after
power off
Function Parameters Table