Use a special charger when charging, and avoid
charging under direct sunlight. Do not charge the
battery repeatedly after the battery is full. Keep
children away from the charging charger.
•
The battery system is not suitable for extended use.
It should be placed in a suitable environment (-
temperature below 40°C, humidity less than 90%),
and charged once with a dedicated charger for at
least three months.
•
Discarded batteries may cause danger to people
and the environment. Be sure to properly discard
them according to the rules of your workplace and
your local laws.
•
Do not apply external force to the battery or drop it
from a high altitude.
•
The lithium battery has an automatic protection
function: if the cell voltage is higher than 3.4V, the
battery system activates for a long period of time
without an output current (≤5A) for 36H, or the cell
voltage is lower than 3.4V, the battery is used for a
long time. When the system is active and no current
is output (≤5A) for 8H, the system will automatically
cut off the contactor protection. If so, re-key the
battery to activate it.
The setting method of indoor/outdoor
mode
Note:
This setting method is for GTJZ1212E machines
only.
NOTICE
GTJZ1212E machine is divided into outdoor machine
and indoor machine.
Indoor machine can only be used indoor.
Outdoor machine can be set indoor mode and
outdoor mode. The maximum working platform
height of outdoor mode is 9m (30ft), and the
maximum working platform height of outdoor model
is 11.9m (39ft).
Indoor mode is strictly prohibited for
outdoor use. Indoor machine is
strictly prohibited for outdoor use.
For outdoor machine, the ground controller can choose
indoor mode and outdoor mode.
•
Select outdoor mode, the maximum working
platform height is 9m (30ft). that is, the platform
cannot rise after reaching 9m (30ft).
•
Select indoor mode, the maximum working platform
height is 11.9 m (39ft). However, when the platform
height rises to 9m, the platform will stop rising and a
sound alarm will appear. "id" will appear on the
platform control box. At this point, return the control
handle to the middle position and release the
handle. Then hold the enable switch of the control
handle and push the handle forward. The platform
can continue to rise to 11.9m.
Indoor/outdoor mode setting steps are as follows
:
1.
Turn the key switch of the ground controller to the
ground control position.
2.
Push the emergency stop button on the platform
controller to the ON position.
3.
Push the emergency stop button on the ground
controller to the ON position while holding down the
enter button for five seconds, and the program
setting interface appears on the display screen.
4.
Press page down key until the display appears "Set
Option", then press the enter button.
5.
When "In or Out door" appears on the screen, then
press the enter button.
6.
At this time, two options "In Door" and "Out Door"
appear on the screen.
7.
Select "In Door" or "Out Door" by clicking page up
and page down keys.
8.
Select "In Door", then press the enter button., The
indoor mode is set successfully.
9.
On the contrary, select "Out Door", then press the
enter button., The outdoor mode is set successfully.
Trouble Diagnosis (Deltatech System)
A machine with this system has two display screens on
the ground controller and platform control box. They
display the machine parameter information and the
trouble types.
Содержание GTJZ0612E
Страница 2: ......
Страница 6: ...This Page Intentionally Left Blank...
Страница 8: ...This Page Intentionally Left Blank...
Страница 12: ...Jul 2020 iv GTJZ0612E 0812E 1012E 1212E Maintenance Manual This Page Intentionally Left Blank...
Страница 86: ...Jul 2020 5 28 GTJZ0612E 0812E 1012E 1212E Maintenance Manual MAINTENANCE PROCEDURES...