409977/B
59
a
In the bottom left corner of your desktop, select the looking glass to search
the operating system.
b
Type "Command", do the search, and open the
Command Prompt
window.
c
Type
ipconfig /all
and press the
Enter
key.
d
Observe the "Physical Address" (MAC address) for the relevant Ethernet
adapter.
e
Write down the information.
f
Close the
Command Prompt
window.
Select the adapter that the Operating Panel is connected to. On the SU90, the
Ethernet adapter is named Simrad Connect.
Prepare the Operating Panel for use.
2
Make the following preparations.
a
Connect the power cable from the Operating Panel to the power outlet on the
uninterruptible power supply (UPS).
b
Connect the Ethernet cable from the Processor Unit to the Operating Panel.
Make sure that you use the correct Ethernet socket on the rear side of the
Processor Unit: ETH1
c
Connect the keyboard and the mouse to USB sockets on the front panel of
the Processor Unit.
d
On the Processor Unit, close any programs that are running, and return to
the desktop.
e
On the Operating Panel, press
Power
, and keep it depressed for a few seconds.
The blue indicator light in the button flashes while the Operating Panel
establishes contact with the Processor Unit. When you start the panel for the
first time the interface must be configured to establish this connection. When
the connection has been made, the blue indicator light is lit permanently.
f
On the Processor Unit desktop, open folder
SIMRAD-Shortcut
.
g
Double-click file
IPandMACaddress.txt
to open it in a text editor.
h
Double-click the URL shortcut to open the Operating Panel configuration page
in the default web browser.
Observe that the Operating Panel configuration page opens on
page 157.237.60.20: 5000
3
Define the configuration parameters.
a
Select
SOP Configuration
on the top menu to open the page.
b
Observe the default values.
If you wish to keep these default values, do nothing. The default values are
well suited if you have one single panel communicating with one single
Processor Unit. For other configurations, see the relevant procedures.
Содержание SU90
Страница 61: ......
Страница 62: ...2020 Kongsberg Maritime...