26
409977/B
Environmental inspection of the Transceiver
Unit
Satisfactory environmental conditions are important to ensure long and trouble-free
operation of the Transceiver Unit. An environmental inspection of the Transceiver Unit
is required to verify the quality of the sonar room.
Prerequisites
The SU90 is installed as specified in the SU90
Installation manual
. You need the
following equipment:
• Thermometer
• Hygrometer
Context
The
sonar room
is the compartment in which the Transceiver Unit is installed.
Procedure
1
Make sure that the compartment ("sonar room") in which the Transceiver Unit is
installed is clean and dry.
2
Make sure that the ambient temperature in the sonar room meets the environmental
specifications.
a
Make sure that the temperature in the sonar room is controlled using a suitable
ventilation system.
b
Record the type of ventilation system that is installed.
c
Make sure that the temperature in the sonar room is monitored.
d
Measure the ambient temperature in the sonar room when the SU90 is switched
off.
e
Record the value in the result table.
3
Make sure that the relative humidity in the sonar room meets the environmental
specifications.
a
Measure the relative humidity in the sonar room.
b
Record the value in the result table.
4
30 minutes after the SU90 has been switched on and put to normal operation,
measure the ambient temperature one more time.
Record the value in the result table.
5
30 minutes after the SU90 has been switched on and put to normal operation,
measure the relative humidity one more time.
Record the value in the result table.
Simrad SU90 Harbour Acceptance Test