30
409977/B
Note
Proper oral communication must exist between the bridge and the sonar room. In the
event of problems or malfunctions:
1
Locate the
Motor Protecting Switch
(S301).
2
Set the switch to position OFF.
Topics
Bridge steps
The hull unit provided with the SU90 is designed to lower the transducer down below
the ship’s hull when the SU90 shall be used. This is a key functionality of the SU90.
It is very important that the hoist/lower function is tested before the SU90 is put to
operational use. In order to test the lower and hoist functionality of the hull unit, two
tasks must be done simultaneously. These tasks are done on the bridge.
Prerequisites
The SU90 is installed as specified in the SU90
Installation manual
. The SU90 system is
turned on and operates normally. Neither tools nor instruments are required.
Context
Certain steps in the two procedures are location specific. The steps marked [
Sonar
room
] are done in the sonar room.
Procedure
1
Make sure that you have sufficient water depth below the keel before you lower
the transducer.
2
[
Sonar room
] Locate the
Motor Protecting Switch
(S301). Set the switch to position
ON
.
3
[
Sonar room
] Locate the
Hoist/Lower Switch
(S302). Set the switch to position
REMOTE
.
4
Lower the transducer to its middle position.
a
On the Operating Panel, press
Middle
.
While the transducer is moving the indicator lamp flashes, and an audible
signal is sounded. When the requested position has been reached, the indicator
lamp is lit, and the audible signal stops.
Simrad SU90 Harbour Acceptance Test
Содержание SU90