8 | Installation
Cable connection and interface
Signal input, network and power supply are wired to the
enclosed terminal block that is to be plugged in on the
rear side.
The instrument is delivered with a 0.3 m SimNet cable
with a standard SimNet plug in both ends. One plug
must be cut off and the wires connected to terminals 3
through 6 according to the color codes shown below.
TERMINAL
NO
SIGNAL
TYPE
COLOR
1
GND
-
Supply
-
2
VCC
+ Supply 12 - 24V DC
-
3
SimNet - H
NMEA2000 channel
Yellow
4
SimNet - C
NMEA2000 channel
Black
5
SimNet - L
NMEA2000 channel
Blue
6
SimNet - S
NMEA2000 channel
Red
7
RS485 A
NMEA0183 (Rx+)
-
8
RS485 GND No connection
-
9
RS485 B
NMEA0183 (Rx-)
-
Any voltages other than those specified in the
product specification, page 29, may cause damage
to the instrument.
Data on the NMEA0183 port will be converted to SimNet/
NMEA2000 format and distributed to other instruments
that are interconnected on the SimNet network.