14 | Operation
KEY
KEY
PRESS
MODE/ACTION
DISPLAY MODE
SETUP MODES
MODE
SETUP
Short
Go to next main display Go to next
Setup
mode
3 sec.
Switch to
User Setup
Switch to main display
SELECT
Short
Increase light level
Select parameter
Adjust parameter
3 sec.
None /
Change to next digit
MODE
SETUP
+
SELECT
Short
Save setting and return to
Setup parameter
10 sec. Enter
Installation
Setup
5 sec
Return to main display
Time out from User Setup is 10 sec. Time out from
Installation Setup is 5 min.
Selecting active display mode
The WI80 can display relative, true and geographic wind
speed and direction.
The instrument will
scroll through these
displays by pressing
the
Mode/Setup
key.
Active mode is indicated by a lit diode in the display.
To calculate true wind, speed data input is required. To
calculate geographic wind, both speed and heading data
input is required. If these data are not available, no value
will be displayed in the LED when True or Geographic
wind is selected.
TRUE
GEO
REL
MODE
SETUP
Содержание IS80 Heading Repeater HR80
Страница 7: ...6 Introduction Blank page...
Страница 13: ...12 Installation Blank page...
Страница 25: ...24 Changing the default settings Blank page...
Страница 30: ...WI80 Manual EN Doc no 20223202...