background image

Installation | 9

Securing the cables

Use the eclosed tie wrap to secure the cables to the 

instrument.

Interconnecting instruments

Interconnect a series of instruments by using a SimNet 

power cable with termination and T-joiners as illustrated 

below.

If the instruments are connected to other SimNet 

compatible products, refer to the manual for those 

products.

Use only 12V as SimNet supply!

SimNet

Supply

(Red disk)

Instrument

Supply

SimNet

T-joiner

SimNet

T-joiner

SimNet

T-joiner

12-24V

12V

Содержание IS80 Heading Repeater HR80

Страница 1: ...www simrad yachting com A brand by Navico Leader in Marine Electronics Manual Simrad IS80 Wind Instrument WI80 English...

Страница 2: ...the product and the documentation at any time Updated manuals are available from our website www simrad yachting com and are free to download Copyright 2008 by Navico Holding AS Document no 20223202 R...

Страница 3: ...are used 3 s Time indication 1 3 5 or 10 seconds SELECT 3 s Single key press with time indication MODE SETUP SELECT 3 s Combined key press with time indication A 1 A 2 SELECT Repeated key presses on...

Страница 4: ...on and interface 8 Securing the cables 9 Interconnecting instruments 9 3 Operation 13 Turning the WI80 on 13 Using the keys 13 Selecting active display mode 14 Bargraph 15 Backlighting 16 Error Alarm...

Страница 5: ...4 WI80 Wind indicator Light bank selection 23 5 Spare parts 25 Spares and auxiliaries 25 SimNet cables and accessories 25 6 Specifications 27 Technical specifications 27 Dimensional drawing 28...

Страница 6: ...eration in sunshine Instrument layout The WI80 display includes bargraph dial with pointer and LED display Modes of operation and units for measure are indicated by monitor diodes The instrument is op...

Страница 7: ...6 Introduction Blank page...

Страница 8: ...mounting the unit where it is easily exposed to sunlight as this may unintendedly overheat the unit Panel mounting The mounting surface must be flat and even to within 0 5 mm Drill 4 mounting holes a...

Страница 9: ...r codes shown below TERMINAL NO SIGNAL TYPE COLOR 1 GND Supply 2 VCC Supply 12 24V DC 3 SimNet H NMEA2000 channel Yellow 4 SimNet C NMEA2000 channel Black 5 SimNet L NMEA2000 channel Blue 6 SimNet S N...

Страница 10: ...series of instruments by using a SimNet power cable with termination and T joiners as illustrated below If the instruments are connected to other SimNet compatible products refer to the manual for tho...

Страница 11: ...ding when the input type is changed from SimNet to Demo Refer also to the Operation flow chart in the Operation section The pointer position will change accordingly as shown in the table SIGNAL INPUT...

Страница 12: ...h negative value negative sign The illustration below illustrates the required key presses to offset the angle to 12 1 Range 99 Default 0 0 SELECT MODE SETUP SELECT 1 s MODE SETUP SELECT 1 s 1 s SELEC...

Страница 13: ...12 Installation Blank page...

Страница 14: ...ter approximately 3 seconds the instrument is operative Default Relative wind Before the instruments is ready to operate the default settings should be checked and changed if other values are preferre...

Страница 15: ...main display Time out from User Setup is 10 sec Time out from Installation Setup is 5 min Selecting active display mode The WI80 can display relative true and geographic wind speed and direction The i...

Страница 16: ...ncreased wind speed starting from the right side max 10 diodes are lit PORT STBD 150 210 2 lit diodes per 2m s increased wind speed starting from both sides max 10 diodes on each side PORT STBD 210 33...

Страница 17: ...ium Off 9 High Off Level 8 and 9 are for bright daylight The instrument will return to normal operation 1 second after the last key press Range 0 9 Default value 2 If several instruments are connected...

Страница 18: ...ry limited amount of preventive maintenance If the unit requires any form of cleaning use fresh water and a mild soap solution not a detergent It is important to avoid using chemical cleaners and hydr...

Страница 19: ...play Damping Damping 0 Damping 1 Damping 2 Damping 3 Wind Speed Alarm Limit Adjust limit Wind Shift Alarm Limit Adjust limit Speed Unit m s kts mph km h bu Light Bank Selection Simrad Gr 1 Gr 2 Gr 3 G...

Страница 20: ...splay will respond to changes in wind readings The setting affects both the LCD and the pointer The higher the damping factor the more stable display reading on the instrument Range 0 3 Default 0 The...

Страница 21: ...on one of the keys The range is defined by the selected speed unit SPEED UNIT RANGE m s 000 031 kts 000 060 mph 000 069 km h 000 111 BEAU 000 011 Default value Maximum range for the selected speed un...

Страница 22: ...and reset to present wind angle when an alarm is acknowledged by a short press on one of the keys Range 0 90 Default 090 The alarm is turned off by setting the value to A 000 A 090 SELECT MODE SETUP S...

Страница 23: ...he display SPEED UNIT LCD m s kts mph km h BEAU Default value SPd1 m s The illustration shows required key presses for changing speed units from m s to mph BEAU KM H MPH KTS M S SELECT MODE SETUP SELE...

Страница 24: ...will be effective on the rest of the members in the same group LIGHT BANK LCD POINTER BEEPS Simrad 1 Group 1 1 Group 2 1 Group 3 1 Group 4 1 Group 5 1 Group 6 1 None 1 Default value Simrad If you pre...

Страница 25: ...24 Changing the default settings Blank page...

Страница 26: ...6 6 SimNet cable SDC 02M 24005845 5 m 16 6 SimNet cable SDC 05M 24005852 10 m 33 SimNet cable SDC 10M 24005860 SimNet T joiner SDJ 3p 24006298 SimNet Multijoiner 7p 24006306 SimNet Bulkhead T connect...

Страница 27: ...on 24005729 SimNet cable to Micro C male Cable that connects a SimNet product to a NMEA2000 network 24006199 SimNet cable to Micro C female cable that connects a NMEA2000 product to SimNet 24006363 Si...

Страница 28: ...r When NMEA0183 is selected Weight 0 55 kg 1 21 lb Material ASA PC Luran S Color Black Display Dial 0 359 Marking 10 Illumination Adjustable in 10 steps Digital display Four 7 segment LEDs Environment...

Страница 29: ...28 Specifications Dimensional drawing 172 mm 6 78 172 mm 6 78 136 mm 5 35 152 mm 5 98 136 mm 5 35 153 mm 6 02 21 mm 0 83 47 mm 1 86 10 mm 0 37...

Страница 30: ...WI80 Manual EN Doc no 20223202...

Отзывы: