background image

 

Technical specificat ions |  29 

4 .7  Sim N e t  

Maxim um  num ber of product s connect ed in a net work : .......... 50 

Maxim um  cable lengt h: ....................................... 150 m  ( 500’)  

Bit  rat e of t he bus: .......................................... 250 Kbit / second 

Maxim um  DC current  t hrough a single Sim Net  plug ................ 5A 

Sim Net  pow er supply: .................................................. 12VDC 

Maxim um  drop cable lengt h: ..................................... 6 m  ( 20’)  

Maxim um  t ot al lengt h of all drop cables ( accum ulat ed) :  60 m  ( 200’)  

Environm ent al prot ect ion: Cable and plug/ connect or sy st em  I P66 

Maxim um  t em perat ur e: ..................................... 70 ° C ( 158 ° F)  

Содержание AP24

Страница 1: ...www simrad yachting com A brand by Navico Leader in Marine Electronics Installation manual Simrad AP24 28 EVC Volvo IPS Pilot System with SG05 SimNet Volvo Gateway English ...

Страница 2: ...sions and the English version of this document the English document will be the official version To the best of our knowledge the content in this publication was correct at the time of printing As we are continuously improving our products we retain the right to make changes to the product and the documentation at any time Updated manuals are available from our website www simrad yachting com and ...

Страница 3: ...ol Please take time to read this manual to get a thorough understanding of the system components and their relationship to a complete autopilot system Important text that requires special attention from the reader is emphasized as follows Used to draw the reader s attention to a comment or some important information Used w hen it is necessary to w arn personnel that a risk of dam age to the equipm...

Страница 4: ...stem configuration 8 2 4 Autopilot system layout 9 2 5 SG05 Gateway installation 10 2 6 AP24 and AP28 Control unit installation 11 2 7 RC42 Compass installation 13 2 8 Interfacing 14 2 9 SimNet 15 3 Spare parts 1 9 4 Technical specifications 2 1 4 1 Autopilot System 21 4 2 AP24 Control Unit 23 4 3 AP28 Control Unit 24 4 4 SG05 Gateway 25 4 5 RC42 Rate Compass 26 4 6 AT10 SimNet NMEA0183 converter ...

Страница 5: ...4 SG05 Installation manual 4 8 IP protection 30 ...

Страница 6: ...a transfer and control of Simrad products integrated in a total steering and navigation system 1 2 How to use this m anual This manual is intended as a reference guide for installing and maintaining the Simrad SG05 Gateway and other components in an autopilot system Please take time to read this manual to get a thorough understanding of the system components and their relationship to a complete au...

Страница 7: ...play shows the serial number and software version for the control unit The shown readout is only an example Sim Net sources Serial number and software version for other SimNet sources can be found under the control unit User setup menu Refer to Manual source selection in the autopilot operator manual ...

Страница 8: ...o verify proper operation of the system refer to the check list below 2 1 I nstallation checklist 1 Determine the system configuration you are installing Page 8 2 Perform the hardware installation Page 10 3 Connect SimNet devices to SimNet page 15 4 Perform Set up refer to Operator manual 5 Test Autopilot Operation at Sea refer to Sea Trial instructions in the Operator manual 2 2 Unpacking and han...

Страница 9: ...stem prior to beginning the installation An autopilot basic single station system with optional station is shown in Figure 2 1 Plan your cabling and configure the SimNet network in accordance with chapter 2 9 on page 15 As most of the units are communicating on a common network SimNet with identical connectors the installation is simple Try to mount the units within the standard cable length suppl...

Страница 10: ...V WIND TURN STBY DRIFT NO AUTO MENU Figure 2 1 RC42 Rate Compass AP24 Control Unit AP28 Control Unit SG05 Gateway 24 AP MODE MENU AUTO STBY TURN 10 10 PWR 1 1 12V SimNet supply SimNet cable with termination To EVC connect point PWR NAV WIND TURN STBY DRIFT NO AUTO MENU Figure 2 2 The EVC connect point is a connector on the Volvo Penta Autopilot Interface kit It can be ordered from Volvo Penta unde...

Страница 11: ...to section 2 9 on page 15 Connect 12V SimNet supply Refer to Figure 2 10 for correct polarity Connect the 1 m pigtail plug into mating connector of the Volvo Penta Autopilot Interface Figure 2 4 SG05 has a built in LED that will alternate with 1 Hz when the unit is up running Figure 2 3 SG05 mounting Simrad SG05 Gateway Autopilot Interface kit Volvo Penta part number 3819744 Autopilot Gateway EVC ...

Страница 12: ...y com ing into contact w ith the electrical connectors Panel m ounting The mounting surface must be flat and even to within 0 5 mm Drill the 4 mounting holes and make a panel cut out according to supplied template Connect the SimNet cable s to the control unit connector s To daisy chain units remove the blocking plug with a pair of pliers Use the supplied 19 mm screws to fasten the control unit to...

Страница 13: ...12 Operation Optional bracket m ounting Figure 2 6 AP24 Bracket mounting Figure 2 7 AP28 Panel mounting ...

Страница 14: ...g the mounting location As the heading is displayed on the control unit the heading sensor can be mounted at a remote location The compass can be mounted on deck or bulkhead athwart ship or along ship Some of the products connected to the SimNet network may have a heading offset feature This will compensate for the mechanical offsets that may be a result of the selected location and orientation of...

Страница 15: ...t should be mounted 0 75 1 m above the wheel house on a non magnetic stand The compass face plate is the TOP Never mount it upside down Level the sensor as close to horizontal as possible Use the supplied mounting kit and drill holes through the centre of the slots Connect the compass to an available SimNet connector in the SimNet backbone 2 8 I nterfacing With the autopilot system there are sever...

Страница 16: ...e extension in line cable joiners are available Total length of SimNet cable installed in a system should not exceed 150 meter 500 If you plan to extend your SimNet system in the future it may be advantageous to prepare for it by adding a few T joiners in central locations The T joiners provide easy access to the network and can be replaced with a new product or the new product can be connected vi...

Страница 17: ... the number and type of products connected For additional information about SimNet ask for the separate SimNet Manual Figure 2 10 SimNet Power connection AP24 Control Unit IS20 Instrument IS20 Instrument 24 AP MODE MENU AUTO STBY TURN 10 10 PWR 1 1 Multijoiner RC42 12V SimNet supply SimNet cable without termination Wind transducer AT45 NX45 NavStation Active depth transducer Analog speed temp sens...

Страница 18: ... Active depth transducer Analog speed temp sensor Wind transducer AT45 PWR NAV WIND TURN STBY DRIFT NO AUTO MENU To EVC connect point Termination plug Figure 2 12 SimNet network expanded system 1 Maximum total length of SimNet cables is 150 m 500 ft 2 Drop cables must not exceed 6 m 19 ft of length and the total length of drop cables must not exceed 60 m 200 ft 3 Equipment should not be daisy chai...

Страница 19: ...18 Operation Blank page ...

Страница 20: ...nsisting of 22095483 Cabinet corners 6 44165181 Screw 3 5x19 4 24006355 SimNet blocking plug 22096820 Optional mounting bracket kit 24006355 SimNet blocking plug 22096572 AP28 Weather Cover SG0 5 Sim Net Volvo Gatew ay 24006793 SG05 SimNet Volvo Gateway w acc 24006686 SG05 SimNet Volvo Gateway 44149292 Screw 3 5x10 2 RC4 2 Rate Com pass 22090195 RC42 Rate Compass w accessories 22081442 Installatio...

Страница 21: ...et to Micro C male Adapter cable 0 5 m for SimNet products in a NMEA2000 network 24005860 SimNet T joiner 3p 24006298 SimNet multijoiner 7p 24005894 SimNet termination plug 44172260 SimNet In line joiner w o termination 44172278 SimNet In line joiner w termination 24005936 AT10 Universal NMEA0183 converter AS000469 AT40 NMEA0183 interface to NX40 AA010169 AT45 NMEA0183 interface to NX45 24005878 S...

Страница 22: ...n 2002 08 Automatic Steering control Rudder Drive Volvo Penta EVC Parameter selection Automatic Autotune with manual override Sea state control Adaptive sea state filter or manual Language selection Dutch English French German Italian Norwegian Spanish Swedish NMEA2000 interface Via SimNet port and SimNet NMEA2000 adapter cable Heading sensor RC42 Rate Compass Course Selection Push keys Rotary kno...

Страница 23: ... Rudder angle PGN127245 Speed PGN128259 PGN129026 PGN130577 Depth PGN128267 Wind angle speed and direction PGN130306 Position PGN126992 PGN127250 PGN127258 PGN129025 PGN129026 PGN129029 PGN129033 PGN130577 NAV PGN129283 PGN129284 PGN129285 PGN129029 PGN129291 Log PGN128275 Sea temperature PGN130310 PGN130311 Parameter Group Number ...

Страница 24: ... Network load factor NL 2 SimNet ports input output 2 Display Type Backlit LCD matrix display Resolution 130 x 79 pixels Illumination Red or white Adjustable in 10 steps Safe distance to compass 0 3 m 1 0 ft Environmental Protection IP56 from front IP43 from back Temperature Operating 0 to 55 C 32 to 130 F Storage 30 to 70 C 22 to 158 F Figure 4 1 AP24 Control Unit dimensions Mounting bracket is o...

Страница 25: ...Network load factor NL 3 SimNet ports input output 2 Display Type Backlit LCD matrix display Resolution 130 x 104 pixels Illumination Red or white Adjustable in 10 steps Safe distance to compass 0 3 m 1 0 ft Environmental Protection IP56 from front IP43 from back Temperature Operating 0 to 55 C 32 to 130 F Storage 30 to 70 C 22 to 158 F Figure 4 2 AP28 Control Unit dimensions Mounting bracket is o...

Страница 26: ...vironmental Protection IP44 Supply and interface 12V via SimNet Power consumption 0 9 W SimNet Network load factor NL 2 SimNet ports input output 2 Safe distance to compass 0 5 m 1 6 ft Temperature range Operation 0 to 55 C 32 to 130 F Storage 30 to 70 C 22 to 158 F Mounting Bulkhead mount Figure 4 3 SG05 Dimensions ...

Страница 27: ...le supplied 5 5 m 18 SimNet cable with connector Mounting Deck or bulkhead Automatic Performance Calibration Automatically activated from control head Rate offset Automatically adjusted continuously Deviation control Automatic Heading output Rate sensor stabilized Static Performance Roll Pitch 35 Accuracy 3 degrees after calibration Repeatability 1 0 Dynamic Performance With random excitation of 1...

Страница 28: ...Technical specifications 27 Figure 4 4 RC42 Rate Compass Dimensions 4 6 AT1 0 Sim Net NMEA0 1 8 3 converter ...

Страница 29: ...DBT x DPT 0 5 11 x GGA x GLL 0 52 x HDG 4 x HDM x2 HDT 4 x HSC 0 1 MTW 0 2 x MWV Relative Wind 1 x MWV True Wind 1 x RMA x RMB 0 5 x RMC 0 5 x RSA 3 33 VHW 0 5 x VTG 0 5 x VLW 0 2 0 51 x VWR x WPL x XTE x ZDA 0 5 x ZTG x Open cells indicates no transmission or reception 1 Applies only for units with P N S N code AA 2 Applies for units with P N S N code BA onwards ...

Страница 30: ...th 150 m 500 Bit rate of the bus 250 Kbit second Maximum DC current through a single SimNet plug 5A SimNet power supply 12VDC Maximum drop cable length 6 m 20 Maximum total length of all drop cables accumulated 60 m 200 Environmental protection Cable and plug connector system IP66 Maximum temperature 70 C 158 F ...

Страница 31: ...objects up to 50 mm e g accidental touches by hands 1 Protected against vertically falling drops of water e g condensation 2 Protection against solid objects up to 12 mm e g fingers 2 Protected against direct sprays of water up to 15 from the vertical 3 Protection against solid objects over 2 5 mm tools wires 3 Protected against sprays to 60 from the vertical 4 Protection against solid objects ove...

Страница 32: ...AP24 28 EVC Volvo IPS Pilot System with SG05 SimNet Volvo Gateway EN Doc no 20223210 Rev A ...

Отзывы: