17. Remove three screws that attach motor mount
bracket to the appliance chassis. See Figure 6.17.
18. Remove the motor and bracket from the chassis until
the electrical connector is visible. See Figure 6.18.
19. Disconnect the electrical connector to the motor. See
Figure 6.18.
20. Install the replacement motor on the bracket
.
21. Reconnect the electrical connector between the
motor and the appliance. See Figure 6.18.
22. Install the motor mount bracket to the chassis with
three screws. See Figure 6.17.
23. Install the replacement reflector rod. Install the left
end of the rod into the bushing in the left rear of the
cavity. Align the rubber coupler with the motor shaft.
Shift the rod to the right until the rubber coupler fully
engages the motor shift. See Figure 6.15.
24. Reinstall metal bracket in front of faux motor. Install
three screws to fasten the panel. See Figure 6.16.
25. Install the flame screen panel and attach with six
screws. See Figure 6.14.
26. Install the brick panel into the rear of the cavity by
attaching with one screw. See Figure 6.13.
27. Install refractory panels. Align tabs on back edge
of the panel with the slots in the rear appliance
cavity. Once the tabs are engaged, carefully
install the front edge of the appliance cavity. Take
care to apply even pressure to prevent damage to
the replacement panels. Fold sheet metal tabs on
each side of front edge of opening to secure front
edge of refractory. See Figure 6.11 & 6.12.
28. Reconnect the five connectors from the Blower/
Heater module to the appliance. See Figure 6.10.
29. Carefully align the Blower/Heater module horizontally
with the opening of the appliance. Install it straight
into the opening so that the back edge interlocks
with the back wall of the appliance.
30. While supporting the Blower/Heater Module, install
the four screws across the upper face of the
appliance. See Figure 6.9.
31. Install the four thumb screws and metal angle
bracket in the upper rear of the appliance cavity.
See Figure 6.8.
32. Rotate log ember bed and align with floor of opening.
Engage back side of ember bed into the opening.
Pivot the front of the ember bed into potion flat on
the floor of the opening. Take care not to pinch
wiring under log ember bed.
33. Align the grate, with the retained screws, with the
steel brackets under the ember bed. Ensure that
wiring is not pinched between log ember bed and
steel bracket.
34. Install and tighten the screw in each end of the grate.
See Figure 6.3.
35. Install rubber plugs into holes in each end of grate.
See Figure 6.3.
36. Install glass into bottom retainer channel.
37. Install C-channel on top edge of glass panel.
38. Align C-channel with screw holes in appliance.
See Figure 6.2.
39. While supporting glass, install both screws through
top C-channel retainer into appliance.
40. Install front by aligning the tabs on its back side with
the spring clips on the face of the appliance. Press
evenly with two hands to fully engage the front to the
appliance.
Figure 6.2 Top Glass Retainer Screw Location