Features
Conforms to EN54-2 and EN54-4 Standards*
Control panel hardware feature summary:
•
160 Character super-twist LCD readout
(4 lines x 40 characters/line)
•
Membrane keypad with insert labels
•
Expandable up to 512 points/32 zones
Supports conventional and addressable
inputs:
•
MAPNET II
®
Addressable Devices including
isolator modules
•
TrueAlarm
®
Addressable Analog Sensors**
•
Nonvolatile flash EPROM memory
•
Temperature compensated battery charger
•
Battery supervision (low/no battery)
Software Features:
•
Four operator access levels
•
300 Event historical alarm and fault logs
•
Zonal and point alarm information
•
Alarm resound feature
Programmable:
•
Site specific programmable keys/LEDs
•
Powerful custom control provides maximum
flexibility
Optional Voice Evacuation and Fire Brigade
phones:
•
Single, dual, and triple channel
•
Custom voice messages and tones
•
2-Way fire brigade voice communications
•
25 W and 100 W, 25 VRMS Amplifiers
Interface to Remote:
•
MINIPLEX
®
Transponders
•
4604-9202UK Remote LCD Annunciator for
supplementary operations
Optional Modules:
•
4120 Network Interface
•
Sounder outputs
•
Conventional and addressable inputs
•
Control relays with feedback
•
Mimic panel modules
•
Expansion power supplies
PULL DOOR TO OPEN
EMERGENCY OPERATING
INSTRUCTIONS
INDICATION OF ALARM, FAULT WARNING, OR DISABLED CONDITION:
- GENERAL VISIBLE INDICATOR AND AUDIBLE INDICATOR ON.
TO VIEW SUPPRESSED ALARM, FAULT, OR DISABLED INDICATIONS:
- PRESS "REVIEW" KEY LOCATED UNDER EACH VISIBLE INDICATOR.
- REPEAT UNTIL ALL SUPPRESSED INDICATIONS HAVE BEEN DISPLAYED.
TO SILENCE THE LOCAL AUDIBLE INDICATIONS:
- PRESS "PANEL SILENCE" KEY.
TO SILENCE THE ALARM SIGNALS:
- PRESS "SOUNDER" SILENCE/RESOUND" KEY.
TO RESTORE SYSTEM TO NORMAL:
-PRESS "RESET" KEY.
SYSTEM
FAULT
POWER
SITE SPECIFIC PROGRAMMABLE KEYS/LEDS
RESET
PANEL
SILENCE
FIRE
ALARM
REVIEW
ALARMS
FAULT
REVIEW
FAULTS
SOUNDER
FAULT/DISABLED
DISABLE/ENABLE
SOUNDERS
SOUNDERS
SILENCED
DISABLEMENT
REVIEW
DISABLED
ZONES
SOUNDER
SILENCE/RESOUND
*** System is Normal ***
09:36:24 MON 05-APR-1999
4100
FIRE ALARM CONTROL
4100/4120 Series Control and Indicating Equipment
(shown as a 6 unit panel with optional voice control)
Description
Simplex 4100/4120 Series Control and Indicating
Equipment provide an extensive and powerful feature
list to satisfy a wide variety of applications and local
requirements. They are on-site programmable to
provide mapping logic for inputs and outputs and for
custom labeling additions and revisions. Their flexible
site-specific software features can be quickly and
securely generated, modified, and archived by trained
service personnel using computer based programming
tools. With this flexibility, last minute changes can be
made on-site, minimizing delays in job completion.
Input point expansion is available up to a maximum of
512 points in any combination of input types.
NOTE
: When these c.i.e. products are factory configured for 4120
Network Control panel operation, substitute 4100 for 4120.
Contact your local Simplex representative for additional
information about the 4120 Network.
* Refer to pages 6 and 7 for additional information on EN54 compatibility and
LPC testing status.
** MAPNET II addressable communications is protected under U.S. Patent #
4,796,025. TrueAlarm addressable smoke detection operation is protected
by one or more of the following U.S. Patents: 5,155,468; 5,173,683;
5,543,777; 5,400,014; 5,552,765; 5,552,763; DES. 377,460.
True
Alarm
®
Fire Alarm Controls
EN54 Compliant*
4100 and 4120 Series Fire Alarm
Control and Indicating Equipment (c.i.e)
© 1999 Simplex Time Recorder Co. All rights reserved.
S4100-0025 (EN54) 5/99