One-Way Communications Systems:

 

Single and dual channel audio

 

Triple channel audio with a dedicated microphone
channel

 

Multiple supervised remote microphone inputs

 

Multiple built-in selectable tones

 

Spoken voice coding

 

Multiple digitally recorded human voice messages

 

Digitized voice/tone generation

 

Automatic or manual audio control

 

Separate evacuation, drill, and optional “all clear”
voice messages and tones

 

Ready-to-talk indicator for microphone

 

Optional synchronized redundant voice tone
generator

 

Local panel speaker for tone/message broadcast
verification

 

MINIPLEX voice transponders for distributed audio

Fire Brigade Telephone Systems:

 

Telephone to audio interface

 

Multiple remote master phones

 

Ring signal on remote telephone indicates call
request

 

Telephone circuits are supervised for open and short
circuit conditions

General

Systems with audio provide one-way voice
communication, alarm tones, and/or digitally
prerecorded voice messages to alert occupants of fire or
other emergency situations. Evacuation signaling may
be automatically generated via alarm initiated event
programs in the 4100 Master Controller or by
firefighting personnel operating the system microphone.
The system may also be equipped with a Fire Brigade
Master Telephone module to provide the Fire
Commander with two-way communications with
firefighters or fire wardens located remotely throughout
the building.

Operation

Audio Control Board provides routing and pre-
amplification of digitized alarm tones and voice
messages. Actual tones and voice messages are digitally
recorded and stored in the audio control board’s
message memory. When called upon, an integral Voice
Tone Generator (VTG) recreates the audio waveforms
of the prerecorded voice/tone messages with completely
natural sound. The Audio Control board receives
instructions from the Master Controller to direct the
routing of the audio tones, codes, prerecorded or
manual voice messages to the appropriate audio output
circuits.

Simplex Time Recorder Co.

5

S4100-0025 (EN54)  5/99

PULL DOOR TO OPEN

EMERGENCY OPERATING

INSTRUCTIONS

INDICATION OF ALARM, FAULT WARNING, OR DISABLED CONDITION:
- GENERAL VISIBLE INDICATOR AND AUDIBLE INDICATOR ON.

TO VIEW SUPPRESSED ALARM, FAULT, OR DISABLED INDICATIONS:
- PRESS "REVIEW" KEY LOCATED UNDER EACH VISIBLE INDICATOR.
- REPEAT UNTIL ALL SUPPRESSED INDICATIONS HAVE BEEN DISPLAYED.
TO SILENCE THE LOCAL AUDIBLE INDICATIONS:

- PRESS "PANEL SILENCE" KEY.
TO SILENCE THE ALARM SIGNALS:
- PRESS "SOUNDER" SILENCE/RESOUND" KEY.
TO RESTORE SYSTEM TO NORMAL:
-PRESS "RESET" KEY.

SYSTEM
FAULT

POWER

SITE SPECIFIC PROGRAMMABLE KEYS/LEDS

RESET

PANEL
SILENCE

FIRE
ALARM

REVIEW

ALARMS

FAULT

REVIEW

FAULTS

SOUNDER

FAULT/DISABLED

DISABLE/ENABLE

SOUNDERS

SOUNDERS
SILENCED

DISABLEMENT

REVIEW
DISABLED
ZONES

SOUNDER

SILENCE/RESOUND

***   System is Normal   ***

09:36:24                              MON   05-APR-1999

4100

        FIRE  ALARM  CONTROL

One-Way Voice

Communications Microphone

Two-Way Firefighter

 Master Phone

Telephone Circuit

Selector Switches

Master Controller

Audio Control Switch Module

Local Panel

Speaker

Voice Communication Components

 Audio Component Details

Содержание TrueAlarm 4100 Series

Страница 1: ...MAL PRESS RESET KEY SYSTEM FAULT POWER SITE SPECIFIC PROGRAMMABLE KEYS LEDS RESET PANEL SILENCE FIRE ALARM REVIEW ALARMS FAULT REVIEW FAULTS SOUNDER FAULT DISABLED DISABLE ENABLE SOUNDERS SOUNDERS SILENCED DISABLEMENT REVIEW DISABLED ZONES SOUNDER SILENCE RESOUND System is Normal 09 36 24 MON 05 APR 1999 4100 FIRE ALARM CONTROL 4100 4120 Series Control and Indicating Equipment shown as a 6 unit pa...

Страница 2: ...AULTS FAULT DISABLE ENABLE SOUNDERS SOUNDER FAULT DISABLED SOUNDER SILENCE RESOUND SOUNDERS SILENCED REVIEW DISABLED ZONES DISABLEMENT NEXT PREV System is Normal 09 36 24 MON 05 APR 1999 4 X 40 LCD READOUT LED backlighted during normal conditions and abnormal operating conditions provides up to 40 characters for custom label information EXTENDED FUNCTION KEYPAD accessible with door open select and...

Страница 3: ...rammed for temporal code or march time code RS 232 Dual Port Communication Module Up to four additional RS 232 modules total Each port can be vectored by event category Auxiliary Control Relays Built in fuse protection per contact Feedback tracks on off status of remote devices 4100 3001 four CPU controlled relays DPDT contacts rated for 2 A 24 VDC 4100 3002 four CPU controlled relays DPDT contact...

Страница 4: ... to 830 Hz in 2 5 seconds recommended for fire alarm and no other purpose High Low Free running signal with a high frequency of 750 Hz for 100 msec and a low frequency of 500 Hz for 400 msec Horn Continuous 500 Hz tone primarily used for coded systems Chime 600 Hz fundamental tone with a 1 5 sec duration used as a free running tone or for coded operation Beep 500 Hz tone of 0 7 sec on 0 7 sec off ...

Страница 5: ...des routing and pre amplification of digitized alarm tones and voice messages Actual tones and voice messages are digitally recorded and stored in the audio control board s message memory When called upon an integral Voice Tone Generator VTG recreates the audio waveforms of the prerecorded voice tone messages with completely natural sound The Audio Control board receives instructions from the Mast...

Страница 6: ...e 3001 Four Relays 2A with Feedback 15 mA 75 mA 2 Internal 3002 Four Relays 10A with Feedback N A 15 mA 175 mA 4 Internal 3003 Eight Relays 3A with Feedback 2 As Required 25 mA 280 mA 2 Internal Power Supply Options 4100 4120 Description LPC Status Quantity Standby Alarm Module Size 0157 8 A Intelligent Power Supply with Charger 230 VAC 6 Internal 0158 8 A Power Supply 230 VAC 0164 Temperature Com...

Страница 7: ...antity Standby Alarm Module Size 4120 6014 Modular Network Interface Board 35 mA 35 mA 2 Internal 4120 0142 Wired Media Card 40 mA 40 mA 4120 0143 Fiber Optic Media Card N A As Required 25 mA 25 mA N A Cabinets and Accessories 4100 4120 Description LPC Status Quantity Standby Alarm Module Size 2052 Four Unit 2053 Six Unit with Glass Door 2062 Four Unit 2063 Six Unit with Solid Door Choose One Per ...

Страница 8: ... 4 654 mm 6 3 4 171 mm 26 3 8 670 mm 7 3 4 197 mm 3 3 4 95 mm See chart 3 76 mm 2 1 4 57 mm Installation Detail Side View IMPORTANT Distance between close coupled dual cabinets must be no less than 3 inches 76 mm and no more than 24 inches 610 mm Input Power Requirements Mains Input 230 VAC base models 1 A maximum Mains Input with 230 VAC expansion power supply 2 A maximum Mains Input 4100 0263 10...

Отзывы: