LAMPHOUSE OPTICAL ALIGNMENT
Carefully follow the lamphouse manufacturer’s instructions regarding correct optical alignment
between the lamphouse and projector. The lamphouse is generally aligned to the projector aperture, but
some consoles require positioning the projector to the optical center of the lamphouse.
Never
operate the
lamphouse with the douser open unless the projector is running.
LAMPHOUSE LIGHT SHIELD
Light shields, or nose cones, supplied by the lamphouse manufacturer, may be installed between the
projector shutter guard and the lamphouse snood. Make certain that the nose cone does not obstruct the rotation
of the shutter. Trim or otherwise modify the nose cone as required.
ELECTRICAL CONNECTIONS
All electrical connections to the Apogee terminate in the cabinet mounted on the side of the projector
adjacent to the gear compartment. Loosen the quarter-turn fastener and open the door to access the terminals.
Input voltage is user-selectable by connecting the transformer plug
to one of the two receptacles located on the top of the “Power” printed
circuit board. Connect the plug to J7 for 110 volt operation, or to J8 for
220 volt. After selecting the voltage, apply AC phase and neutral to the
two uppermost terminals on the right barrier strip. This AC input
powers the turret controller, the turret and aperture motors, and the L.E.D.
framing light. An earth ground must be connected to the ground lug at
the lower right corner of the cabinet.
The lower five terminals of the right barrier strip allow power
connections from the automation controller to the picture changeover
and the projector drive motor. The lower five terminals of the left
barrier strip provide connection points to the devices. Voltage to these
devices is generally supplied by, or switched through, the automation
controller. All NEUTRAL connections are common.
Turret inputs connect to the (4) marked terminals on the lower
part of the turret control PCB mounted to the cabinet door.
Picture Changeover
The Apogee is normally shipped with a Strong International
115 V.AC (52-60325) or 230 V.AC (52-60326) picture changeover de-
vice. If ordered separately, connect the changeover leads as follows:
Blk - OPEN
Wht - COMMON
Red - CLOSE
Grn - GROUND
NOTE: These changeover devices require an AC
pulse
to operate.
Connecting the changeover device to a
sustained
AC circuit will
destroy
the electrical coil(s). Check carefully the instructions supplied with the
automation controller and/or the (installer-supplied) switching circuit.