Protect or Disconnect

Circuitry...................... Yes

Line Voltage.............................120 VAC, 50/60 Hz
Initial Clamping Level........200V Peak, 141V RMS
Voltage Protection Rating (UL 1449 3rd Edition, 3,000A):........500V
Protection Modes............................L-N, L-G, N-G
Maximum Current Rating.................15A (1800 W)
EMI/RFI Noise Filtration...45 dB (100 kHz - 1 MHz)
Response Time..............................<1 nanosecond
Single Pulse Energy Dissipation.........1125 Joules
Peak Impulse Current...............................52,000 A
Catastrophic Surge Circuit...............................Yes
Thermal Fusing.................................................Yes

Fuseless/Auto-Resettable...........................Yes

Clamping Level........................................260V

Capacitance..............................30 pf (approx.)

Suppression Modes....Metallic & Longitudinal

Wires Protected.................2 wire, 1 pair (4, 5)

Connectors.......................................RJ-11/45

Bi-directional.................................................Yes

Shielded........................................................Yes

CATV Clamping Level....................................75V

Frequency Range..........................0MHz-2.2GHz

Insertion Loss.......................................  <0.5dB

Connections.................. Female “F”, gold plated

SPECIFICATIONS

AC Specifications:

Universal Cable/Satellite Protection:

Telco Protection:

LAN Protection:

Clamping Level...................................60V ± 5V

Compatibility......................................10/100bT

Connectors.........................................RJ-11/45

Wires Protected........... 4 wires, 2 pair (1,2,3,6)

Current Sense Threshold:

On State, LO...............................................10W

On State, HI...............................................25W

PM8-GAV

PM8-GAV

Surge Protection with Current Sense Control 

Shut off equipment 

when the system is

not in use, while 

leaving power on 

for equipment that 

needs to run 

continuously.

Dimensions          Weight     Qty.            UPC

Dimensions          Weight     Qty.            UPC

13.25"  x  9.5”  x  2.5”      3 lbs.         1              050616008716

17.25"  x  8”  x  14”         19 lbs.          6          50050616008711 

POWER ON/OFF SWITCH

OUTLET # 5

CURRENT SENSE

ENERGIZES OUTLETS

1 -4 WHEN EQUIPMENT

IN OUTLET #5 IS TURNED ON

6 FT. AC POWER C0RD

POWER 

STATUS

INDICATORS

2 PAIRS UNIVERSAL

BIDIRECTIONAL

COAX CONNECTORS

TEL / LAN SURGE

PROTECTION

CURRENT SENSE

LO - HI SELECTOR

POWER ON INDICATOR

FOR OUTLETS 1 - 4

Vanquish Vampire Power!

WARRANTIES*

$100,000 Connected Equipment Limited Lifetime Warranty • Limited Lifetime Product Warranty

*Refer to actual warranty documentation for full details.

L625 REV. A      9/09

®

©2009  Panamax,Inc.  Panamax and the Panamax logo are registered US trademarks of Panamax.  Planrt Safe Power logo is aregistered US trademark of Panamax. 

1690 Corporate Circle, Petaluma, CA 94954  

•  

800-472-5555 or 707-283-5900  

•  

Fax-707-283-5901  

www.panamax.com

MASTER CARTON

SINGLE UNIT CARTON

C

US

LISTED

Planet Safe Power