"Block lock"
If a signal is present at the input (input event, level change low
to high), the RouterNode sends a broadcast to all LockNodes.
You can set whether the LockNodes should respond to the
broadcast (see
). The LockNodes then deac-
tivate the locking devices in which they are installed for the dur-
ation of the input event.
They then no longer react to authorised identification media, no
access is possible. When the signal is no longer present (= no
input event, level change from high to low), the locks are react-
ivated.
If you apply a signal to the input by an intrusion alarm system
during arming, you can thus deactivate the locks of the outer
shell for the duration of the arming of the alarm system (and
prevent the unintentional triggering of the alarm system). How-
ever, you can also freely choose which locks you want to deac-
tivate.
With the outputs (see
) you
can send an acknowledgement back to the intrusion alarm sys-
tem after successful deactivation.
Using this function is not VdS-compliant.
"Amok function"
Similar to the block lock function: If a signal is applied to the in-
put (level change Low to High), the RouterNode sends a
broadcast to all LockNodes. You can set whether the
LockNodes should respond to the broadcast (see
). If there is a signal at the input, the RouterNode sends
a broadcast to all LockNodes which should react to the input.
They then reject all identification media (even normally author-
ised ones); one-time access is only possible with special identi-
fication media (red level).
They then reject all identification media (even normally author-
ised ones), no access is possible. You must explicitly reactivate
the locks with an activation command:
Use WaveNet (response "Activation")
LSM
Activation transponder or card
If you connect an emergency button to an input (see
) and connect it to the amok function, then
you can use the emergency button to block all locks that have
been reached and prevent people from entering (or in the case
of a freely rotating cylinder, from leaving) rooms until they are
explicitly reactivated.
WaveNet
(Manual)
5. WaveNet Manager
78 / 210