The RingCast was able to address
all locking devices.
The RingCast could not be closed.
Possible causes (see also
):
One or more RouterNodes have
not received the data packet.
One or more RouterNodes have
not reached one or more
LockNodes.
Ethernet connection to one or
more RouterNodes is interrupted.
The RouterNodes could have
received the data packet
wirelessly, but could no longer
return their input
acknowledgements due to the
interrupted Ethernet connection.
1. Check the reachability of the
RouterNodes mentioned (see
).
2. Check the reachability of the
LockNodes (see
).
3. Check the last responses of the
LockNodes (see
5.4.5.9 Deleting RingCast
ü
WaveNet Manager opened via LSM (see
)
ü
RouterNodes and LockNodes connected to power supply.
1. In the overview, right-click on the top entry of the RingCast you want to
delete.
9
The window "Edit radio domains" opens.
WaveNet
(Manual)
5. WaveNet Manager
139 / 210