NOTE
Unauthorised access with standard access data
The standard access data can be viewed freely. Unauthorised persons can-
not change the access authorisations, but they can change the network
configuration. You will then no longer be able to reach the device via the
network and will have to reset it.
Some browsers do not transmit spaces at the beginning of the password.
1. Change the default password.
2. Do not start the password with spaces.
Blocking/permitting a change of IP address via the OAM tool
As long as you do not allow the
▼ OAM-Tool allow
, you cannot import
updates via the OAM tool.
ü
Browser interface open.
1. Via | CONFIGURATION | open the tab [PORT].
9
You see the overview of the TCP port settings of RouterNode 2.
2. In the dropdown menu
▼ OAM-Tool allow
select the entry "Yes" (allow
for change of IP by OAM tool) or "No" (block change of IP by OAM
tool0.
3. Click on the button Save .
9
Changing the IP address via the OAM-Tool is blocked/allowed.
Change password
Some browsers do not transmit spaces that are at the beginning of the
password. Therefore do not start the password with spaces.
WaveNet
(Manual)
5. WaveNet Manager
142 / 210
Содержание WaveNet
Страница 1: ...WaveNet Manual 07 04 2020...
Страница 183: ...9 Output is switched WaveNet Manual 5 WaveNet Manager 183 210...